Hide thumbs Also See for X Series:

Advertisement

Quick Links

INSTRUCTION
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Malta Dynamics X Series

  • Page 1 INSTRUCTION MANUAL...
  • Page 2 THE X500 INSTRUCTION MANUAL These instructions apply to the following model(s): X500 Manual Revision Date: March 15, 2021 Please visit www.MaltaDynamics.com for the latest user instruction manual revision available for this product offering as well as supporting documentation. Width: 4’-10” Height: 20’-5”...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS General ------------------------------------------------------------------ 4 Training ------------------------------------------------------------------ 4 Training Topics ---------------------------------------------------------- 4 Under Penalty of Law----------------------------------------------------- 5 Warnings & Limitations------------------------------------------------- General Operation and Initial Setup------------------------------------- 8 Lifting The Unit ----------------------------------------------------------- 10 Maintenance Schedule--------------------------------------------------- 11 Safety Instructions--------------------------------------------------------- 11 Inspection ---------------------------------------------------------------- 12 Initial Quality Inspection--------------------------------------------------- 13 Limited Warranty ----------------------------------------------------------14 Warranty Registration Form ---------------------------------------------- 15...
  • Page 4: General

    GENERAL Malta Dynamics fall protection systems are designed for use where fall hazards exist. This equipment is to be used with an ANSI rated self-retracting device (SRD) with an average arrest force of 900lbs or less. This fall arrest system meets the needs of a construction and industrial worker’s safety requirements.
  • Page 5: Under Penalty Of Law

    WARNING WARNING WARNING Malta Dynamics systems shall be a part of a complete fall protection system. If the user chooses to disregard this warning, he or she is solely responsible for the safety of the entire system and all users.
  • Page 6: Warnings & Limitations

    WARNINGS & LIMITATIONS • Failure to follow these instructions could result in a serious or fatal electrical incident. Read, understand, and follow the instruction manual, assembly drawings, and warnings provided with your system before beginning installation to avoid injury. • Equipment shall only be used by a person trained and competent in its safe use.
  • Page 7 • Use only compatible locking snap hooks or locking carabiners with this product. • Use only approved Malta Dynamics hardware with this product. • Do not attempt to move the system while workers are attached. • The X500 should always be placed on level surfaces as any unexpected movement of the unit could occur resulting in bodily injury or death.
  • Page 8: General Operation And Initial Setup

    components will work in and are acceptable for their specific application and environment. GENERAL OPERATION & INITIAL SETUP Don a full body harness according to the manufacturer’s instructions. Install only ANSI compliant self-retracting lifelines (SRL’s) and personal fall protection according to the manufacturer’s instructions supplied with that product.
  • Page 9 WARNING WARNING WARNING WARNING: Use only ANSI rated SRLs. Adhere to all safety precautions and warnings that come with your SRL. Attach SRLs only to designated anchor points on the system. Failure to do so could lead to serious injury or death. LOCATION: The area where the system is used must be no less capable of supporting twice the weight of the system and the loads applied by the system in event of a fall.
  • Page 10: Lifting The Unit

    Caution must be taken when using self-retracting devices near moving machinery, electrical hazards, sharp edges, or abrasive surfaces. Contact with these elements may cause equipment failure, personal injury, or death. LIFTING THE UNIT FORKLIFT TRANSFER: To properly lift the unit with a forklift, use the built-in forklift pockets.
  • Page 11: Maintenance Schedule

    12 months. All inquiries should be made to Malta Dynamics either by means of phone, fax, or e-mail. Malta Dynamics shall not be held responsible for injuries the user may receieve from a fall if the system or any PPE is used outside of the prescribed scope or any Industrial Code of Practice.
  • Page 12: Inspection

    At no time shall the equipment not be used in a way or for a purpose other than as instructed by the manufacturer. Use of components within the system must adhere to the instructions provided. Using combinations of components including but not limited to lanyards, harnesses, SRDs, and anchors in combinations is strictly prohibited.
  • Page 13: Initial Quality Inspection

    Use this form to maintain records for inspection of this equipment. Inspection Date User Pass Fail 1. Proceed around the machine inspecting welds for cracks or gaps *Cracks in the paint may help identify these areas. 2. Check that bolts and nuts are tightened and not missing. 3.
  • Page 14: Limited Warranty

    LIMITED WARRANTY Malta Dynamics, LLC warrants that the X500 shall be free from defects in material and workmanship that develop under normal use for a period of one year from the date of shipment. The foregoing shall be the exclusive remedy of the buyer and the exclusive liability of Malta Dynamics, LLC.
  • Page 15: Warranty Registration Form

    Malta Dynamics, LLC does not assume responsibility for any accident due to equipment modification or misuse. No claim will be allowed for products lost or damaged in transit. Such claims should be filed with the carrier within fifteen days.
  • Page 16 800-494-1840 MaltaDynamics.com 210 13th Street Malta, OH 43758 USA X500 XSERIES Instruction Manual Manual Revision: MaltaDynamics.com | 800-494-1840 03-15-2021...

This manual is also suitable for:

X500

Table of Contents