(3) ELECTROMAGNETIC IMMUNITY / RADIOFREQUENCY MOBILE EQUIPMENT
Emission test
IEC 60601 test level
Conducted RF
IEC 61000-4-6
150kHz to 80Mhz
EN 61000-4-6
Radiated RF
IEC 61000-4-3
80MHz to 2.5GHz
EN 61000-4-3
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These specifications may not be applicable in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and persons.
(a): The electromagnetic field strength of fixed radiofrequency emitters, such as base stations for mobile telephones
(cellular / cordless), mobile radio, AM/FM radio broadcasts and TV broadcasts cannot be determined exactly by theory.
To assess the electromagnetic environment due to fixed radiofrequency emitters, an electromagnetic environment
measurement must be made. If the measured radiofrequency field strength in the immediate environment where the
product is used exceeds the compliance level specified above, the performance of the product must be tested to verify
whether it conforms to the specification. If abnormal performance is observed, additional measures may be necessary,
such as reorienting or relocating the product.
(b): In the 150 kHz to 80 MHz frequency range, the electromagnetic field strengths must be less than 3V/m.
Cables and
Maximum length
accessories
Micro motor with
motor cord
Foot controller with
cord
AC power cord
Compliance level
3Vrms
3Vrms
3V/m
3V/m
Shield
1.7M
Unshielded
1.7M
Unshielded
1.7M
Unshielded
Electromagnetic environment – guidance
Portable and mobile RF communications
equipment should be used no closer to any
part of the TRAUS SIP10 including cables,
than the recommended separation distance
calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
d = 1.2 √P
d = 1.2 √P 80MHz to 800MHz
d = 2.3 √P 800MHz to 2.5GHz
Where 'P' is the maximum output power rating
of the transmitter in watt (W) according to the
transmitter manufacturer
'd' is the recommended separation distance (m).
The electromagnetic field strength of fixed
radiofrequency emitters, which is determined
by an electromagnetic environment
measurement (a), must be less than the
compliance level in each frequency range (b).
Interference may occur near equipment
marked with the symbol below:
Complies with
RF emissions, CISPR11
Class A / Group 1
IEC 61000-3-2
Harmonic emissions
EN 61000-3-2
Voltage fluctuations /
IEC 61000-3-3
flicker emissions
EN 61000-3-3
Electrostatic discharge
IEC 61000-4-2
(ESD)
EN 610000-4-2
Electrical fast transient /
IEC 61000-4-4
burst
EN 61000-4-4
IEC 61000-4-5
Surge
EN 61000-4-5
Voltage dips, short
IEC 61000-4-11
interruptions and voltage
EN 61000-4-11
variations on power
supply input lines
Power frequency
IEC 61000-4-8
EN 61000-4-8
(50/60Hz) magnetic field
IEC 61000-4-6
Conducted RF
EN 61000-4-6
IEC 61000-4-3
Radiated RF
EN 61000-4-3