Basic Operation With A Parallel I/O Connection; Controlling Operation And Data Output With Parallel I/O - Omron V430-F Series User Manual For Communication Settings

Autofocus multicode reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

2 Controlling Operation and Data Output with Parallel
2-1
Controlling Operation and Data Output
with Parallel I/O
This section explains how to directly connect the code reader to an external device by the I/O cable
and the methods that you can use to control the code reader from the external device.

Basic Operation with a Parallel I/O Connection

2-1-1
This section describes the basic connections and signal flow with external devices.
Operation for one of the primary uses is described in the example below.
Trigger sensor
Example of Trigger Input and OUTPUT signal
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
It turns ON while the code reader is in its Read cycle.
• Output 2: On Match (or Good Read)
It turns ON when there is a Good Read or when it matches with the Master Symbol (if using the
Matchcode function).
• Output 3 : On Mismatch (or No Read)
It turns ON when there is a No Read or when it does not match with the Master Symbol (if using
the Matchcode function).
For how to set up the Output signal assignments, please refer to How to Assign the Output Signals on
page 2 - 10
<Timing Chart>
1. Trigger input
(TRIG signal)
2. Output1
In Read Cycle
3. Output2
Match
(or Good Read)
4. Output3
Mismatch
(or No Read)
*1 For how to change the length of time to hold the signal, please refer to 2-1-8 Change the ON/OFF
timing of the Output Signal (Output 1 to 3) on page 2 - 17
2 - 2
Code Reader
(1) Trigger input
(2) Read is execute.
ON
Read executed by Trigger Input.
OFF
ON
In Read Cycle
OFF
ON
OFF
ON
OFF
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
External devices
(3) Judgement results
are output.
Turns ON on Good Read.
Length of time to hold the signal
can be changed in settings. *1
Turns ON when No Read.
Length of time to hold the signal
can be changed in settings. *1