Change The On/Off Timing Of The Output Signal (Output 1 To 3) - Omron V430-F Series User Manual For Communication Settings

Autofocus multicode reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

1. Output1
Diagnostic
Warning
Use as Ext.Illumination Strobe - (Output 3 Signal Only)
Outputs the signal used to illuminate with external lighting. After enabling Output 3 as Ext.
Illumination Strobe, by default, this output will be ON during the camera exposure time. In this mode,
changing the exposure time also changes the ON time for Output 3.
For advanced applications where more control over Output 3 is required, the Illumination brightness
can be set to Extreme, which will enable the Fixed Light On and Delay Times.
The illumination time length is dependent on the setting for Fixed Light On Time and its timing is
dependent on the setting for Fixed Light Delay Time.
The setting selected for Output Mode is disabled.
• WebLink - Setup - Gear Icon - Advanced Settings - Camera Setup - Lighting
Setting Item
Illumination Brightness
Light Source
Fixed Light On Time
Fixed Light Delay
Time
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
• Output 2: On Match (or On Good Read) Output Mode: Pulse (500ms)
• Output 3: Use as Ext. Illumination Strobe Fixed Light On Time: 100000μs Fixed Light Delay
Time: 5000μs
For how to set up the Output signal assignments, please refer to How to Assign the Output Signals on
page 2 - 10
<Timing Chart>
1. Trigger input
(TRIG signal)
2. Output1
In Read Cycle
3. Output2
Match
(or Good Read)
4. Output3
Use as Ext.
Illumination Strobe
2-1-8

Change the ON/OFF timing of the Output Signal (Output 1 to 3)

Set/Change the length of time the signals assigned to Outputs 1 to 3 are in an ON state and the timing
of when they turn OFF.
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
2 Controlling Operation and Data Output with Parallel
Setting Value
Extreme
Provides ability to set a fixed light-on time and fixed light delay time.
External Strobe
Service Message is not used.
1 to 100000μs
The signal is ON during imaging only for the time set.
1 to 100000μs
The signal turns ON during imaging only after the time set.
ON
Read executed by Trigger Input.
OFF
ON
In Read Cycle
OFF
ON
OFF
ON
From 5ms after start of Read Cycle, ON for 100ms.
OFF
ON for 500ms at 2000ms intervals.
Description
Turns ON on Good Read.
2
2 - 17

Advertisement