6.3. Networks

The networks page shows the current network status of the Multi-Stack Controller and allows for
configuration of the network interfaces.
Figure 27. Nuvation Energy Platform Interface Networks

6.3.1. Networking

There are two configuration cards on this page:
External Network: Controls the External Ethernet network on the Multi-Stack Controller
Bridge: Controls the Internal Ethernet network on the Multi-Stack Controller
Each card shows the following information:
IP Address: The current IP of the Multi-Stack Controller on that network. Displays Unknown if no
address is assigned
Netmask: The current netmask of the connected network. Displays Unknown if no address is assigned
DHCP: Whether DHCP will be used to acquire an address. Displays true for yes, false for no
Required: Whether the network interface is required to be up for proper operation. The Multi-Stack
Controller will wait for up to 2 minutes during power-up for interfaces marked 'required' to come
up before continuing with system startup
Route Metric: The priority of this interface in the internal routing table. Lower values are higher
priority. It is not recommended to change this setting unless advised by Nuvation Energy
MAC Address: The MAC address of the Multi-Stack Controller on the network. This address is not
modifiable
Arrow in the header: A green up-arrow indicates the network interface has a carrier. A red down-
arrow indicates no carrier
If DHCP is disabled on the External Network, the following options will become available: