� Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the oven door on the
top right-hand side of the oven frame.
A. Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)
Range Rating*
120/240 V
120/208 V
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit. For
50 A rated cord kits, use kits that specify use with a nominal 1
(3.5 cm) diameter connection opening.
� A circuit breaker is recommended.
� The range can be connected directly to the circuit breaker box
(or fused disconnect) through flexible or nonmetallic sheathed,
copper or aluminum cable. See the "Electrical Connection -
U.S.A. Only" section.
� Allow at least 6 ft (1.8 m) of slack in the line so that the range
can be moved if servicing is ever necessary.
� A UL listed conduit connector must be provided at each end of
the power supply cable (at the range and at the junction box).
� Wire sizes and connections must conform with the rating of the
range.
� The tech sheet is available online, and the wiring diagram is
located on the back of the range in a plastic bag.
� This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
� Do not use an extension cord.
Electrical Requirements - Canada
Only
A
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Specified Rating of
Be sure that the electrical connection and wire size are adequate
Power Supply
and in conformance with CSA Standard C22.1, Canadian
Cord Kit and
Electrical Code, Part 1 - latest edition, and all local codes and
Circuit Protection
ordinances.
Ampere
A copy of the above code standards can be obtained from:
40 or 50**
50
� Check with a qualified electrical installer if you are not sure the
3
/
"
8
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit. For
50 A rated cord kits, use kits that specify use with a nominal 1
(3.5 cm) diameter connection opening.
� A circuit breaker is recommended.
� This range is equipped with a CSA International Certified
� Do not use an extension cord.
� The tech sheet is available online and the wiring diagram is
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Failure to do so could result in death, fire, or electrical
shock.
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
range is properly grounded.
Range Rating*
120/240 V
120/208 V
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
located on the back of the range in a plastic bag.
Specified Rating
of Power Supply
Cord kit and
Circuit Protection
Ampere
40 or 50**
50
3
/
"
8
13