Premier Mounts 7170-0977 Series Installation Manual

Premier Mounts 7170-0977 Series Installation Manual

Outdoor flat/tilt wall mount

Advertisement

Quick Links

7170-0977 Series
Installation Guide
Outdoor Flat/Tilt Wall Mount
For Samsung OH55
INST-1095 v1.0
Publ. May 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7170-0977 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Premier Mounts 7170-0977 Series

  • Page 1 7170-0977 Series Installation Guide Outdoor Flat/Tilt Wall Mount For Samsung OH55 INST-1095 v1.0 Publ. May 2022...
  • Page 2: Basic Information

    7170-0977 Series Installation Guide BASIC INFORMATION 7170-0977-00 (flat) Wall mount model 7170-0977-01 (Tilt) Display Model OH55 Landscape Installation Configuration Portrait Available by model Tilt feature Fixed at flat, 5 deg, 10 deg , 15 deg Environment Temperature Negative 30 Celsius to 50 Celsius, 24/7 operation Wall application Solid concrete, Hollow Brick, or 3/4"...
  • Page 3: Core Components

    7170-0977 Series Installation Guide CORE COMPONENTS: Mounting Partition / Frame x2 Baffle x2 Hooking Bracket x2 Wall Plate x1 TILT ADAPTER (OPTION): HARDWARE: Tilt Brace x2 1/4-20 x 5” Pan 1/4-20” x 3/4” 1/4” Flat Washer Head Button Head Tilt Coupling...
  • Page 4 7170-0977 Series Installation Guide Mounting frame x2 Torque: 12 to 15 kgf/cm 67 to 84 lbf/in M8 x 16mm 5/16” Split 5/16” Flat 4 Places Hex Bolt Lock Washer Washer Baffle / 1/4-20” x 1/4” Flat partition 3/4” BH Washer...
  • Page 5 7170-0977 Series Installation Guide Flat - Figure A Install flat or tilt brackets, landscape or portrait. 1/4-20 x 5” Security Pan Head x4 Barrel 1/4-20” x 1/4” Flat 3/4” BH Washer If applicable, tilt coupling bracket mounting hole. Mounts to brackets shown in figure c.
  • Page 6 7170-0977 Series Installation Guide Solid Concrete/Brick Brick (Alternative) All hardware, threaded rod, epoxy, and other mounting Use proper mounting guideline per state code. hardware are not supplied. Shown for reference only. Wood Application Use a stud finder to determine the center of the wall studs in the vicinity of the mount and mark the wall.
  • Page 7: Mounting Dimensions

    7170-0977 Series Installation Guide CONCRETE/BRICK 3/4” PLYWOOD-BACKED (OPEN) (OPEN) Requires a minimum of 4 mounting screws on upper slots Requires at least 4 mounting screws into wood stud and 4 and 2 on bottom slots. Shell expansion anchors are suitable mounting screws on the upper slots.
  • Page 8: Security Feature

    7170-0977 Series Installation Guide Cover / Roof (Optional) 50mm mininum gap for ventilation all around UP arrow Route cables through holes on the bracket. Shown: Portrait at 5 deg tilt SECURITY FEATURE SECURITY FEATURE (2) 1/4-20 x 5” Pan Head (Post-leveling Screws) Cable &...
  • Page 9 7170-0977 Series Installation Guide 5.55” [141mm) 8.61” [218.7mm] 11.67” [296.4mm] 14.62” [371.4mm] Flat 5 Deg 10 Deg 15 Deg Landscape Portrait 5.55” [141mm] 9.53” [242.1mm] 13.50” [342.9mm] 17.33” [440.2mm] Flat 5 Deg 10 Deg 15 Deg Page 9...