Pepperl+Fuchs OBD10M-R2000-4EP Manual page 32

2-d laser scanner
Hide thumbs Also See for OBD10M-R2000-4EP:
Table of Contents

Advertisement

2-D Laser Scanner
Troubleshooting
Fault message
on the display
IP address conflict
Pre-fault warning
Fault messages
Fault message
on the display
Internal temperature
too high
Internal temperature
too low
Overload output Qx
Configuration
Device defect // Error
Code xx
32
Green
Red
LED
LED
On
dual flash Normal
On
dual flash Normal
Green
Red
LED
LED
On
On
On
On
Flashes
On
4 Hz
On
On
Off
On
LED Qn Description
Configured IP is already
used in the network
Service life reached
LED Qn Description
Off
Internal temperature too
high—no measurement
possible
Action: Allow device to
cool down
Off
Internal temperature too
low—no measurement
possible
Action: Heat up device
or allow it to heat up
Normal
Short circuit or overload
at Qx;
Action: Eliminate the
short circuit at the corre-
sponding output or
reduce load
Off
Application data for field
evaluation not valid;
Action: Write data to the
device again using DTM
Off
The device is faulty; the
customer is unable to
repair the defect.
Send the device with
details of the error code

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obd30m-r2000-4epObd30m-r2000-4ep-t

Table of Contents