Technical Specifications - Siemens KFV Operating Instructions Manual

Electro-mechanical systems
Table of Contents

Advertisement

Operating instructions
4.5

Technical specifications

Ambient temperature range in the door
(according to DIN EN 14846 class K,M,L,N,P)
Relative humidity
Protection class
Operating voltage
Operating current standby / standby
Operating current for motor control
Reverse polarity protection
Release On
Release Off
Internal with Pulldown resistance
Dimensions
Cable length at 0.14 mm²
Cable length at 0.5 mm²
H47.ELEKS005EN-00
Environmental conditions
T
- 25 °C to + 70 °C
UM
20% to 80% (non-condensing)
IP 40
Electrical data
U
24 V DC (19 V DC to 32 V DC)
B
I
Type 30 mA
ST
I
Type 500 mA (max. 1000 mA)
B
U
- 50 V
Verp
Input signal terminal 4
U
> 7.0 V DC
KL4.ON
U
< 4.0 DC V
KL4.OFF
R
4.7 kΩ
Pulldown
Dimensions
W x L x D
16 mm x 252 mm x 49 mm + secondary sash
thickness
Cable lengths
LIYCY
≤ 24 m
LIYCY
≤ 50 m
Electromechanical systems
A-opener 2.1
02.2019
15/18