Display Of Status Led - Siemens KFV Operating Instructions Manual

Electro-mechanical systems
Table of Contents

Advertisement

Electromechanical systems
A-opener 2.1
4.4

Display of status LED

LED
Buzzer
Green
Flashes
green
Flashes
yellow
Yellow
Red
Red
Flashes red
• To lock or unlock the door with the cylinder key, always turn it as far as it will go. The cylinder key must then be turned back
some way before it can be removed from the cylinder lock.
• If the door is released automatically, it remains open for 3 s and an acoustic signal will be audible for this period.
• The AS3500/3600 multi-point lock with A-opener 2.1 will return to the locking position if the door is not opened during this
period. The AS3500/3600 multi-point lock with A-opener 2.1 locks mechanically automatically if the door is closed.
• Opening the door via cylinder lock, lever handle, or horizontal actuating rod is only admissible during motor shutdown.
• If the AS 3500/3600 has been locked via the profile cylinder, the main deadbolt is extended and the lever handle is therefore
blocked (child-proof lock). An electric opening process may not be carried out in this case.
14/18
Description
Disturbance-free
Opening signal is present at
terminal 4.
Faulty contact of the connec-
ting clamps
Limited function
Supply voltage defective
Operating voltage exceeded
Error in the control unit
Block drive with opening
procedure
02.2019
Action
Check connecting clamps
Have the supply voltage checked
Check the ambient temperature
Check for mechanical sluggishness
Check whether the main deadbolt
has been extended via the profile
cylinder (child-proof lock active /
lever handle blocked)
= LED lights up
Operating instructions
Comments
Contact service partner if the
fault persists
Contact service partner
Contact service partner if the
fault persists
Contact service partner
Contact service partner if the
fault persists
= LED flashes
H47.ELEKS005EN-00