Wiring The Power Inputs - Planet TSN-6325-8T4S4X Quick Installation Manual

Industrial layer 3 managed tsn switch
Table of Contents

Advertisement

3. Wiring the Power Inputs

The Upper Panel of the Industrial Managed Switch indicates an inlet
power socket and consists of one green terminal block connector within
6 contacts. Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for
Power 1, or Contacts 5 and 6 for Power 2.
 DC 9-48V, AC 24V
Figure 3-1: TSN-6325-8T4S4X Upper Panel
Tighten the wire-clamp screws for preventing the wires from loosening.
Figure 3-2: Power 1 & 2 Pins of Terminal Block Connector
1. The wire gauge for the terminal block should be in the
range from 12 to 24 AWG.
2. Please check the AWG Ampere specification before
Note
connecting PLANET Industrial Managed Switch.
DI0
DI1 DO0 DO1
GND
1 2 3 4 5 6
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Alarm
PWR2
DC Input: 9-48V
, 5A max.
AC Input: 24V
, 2A max.
1
2
3
4
V+
V-
Power 1
GND
5
6
V+
V-
Power 2
5