Aseptico ADU-17A Operation And Maintenance Instruction Manual

Aseptico ADU-17A Operation And Maintenance Instruction Manual

Express air portable dental system

Advertisement

Quick Links

OPERATION and MAINTENANCE
INSTRUCTION MANUAL
ADU-17A Express Air Portable Dental System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADU-17A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aseptico ADU-17A

  • Page 1 OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU-17A Express Air Portable Dental System...
  • Page 2: Table Of Contents

    To prevent injury to people and damage to property, INDICATIONS FOR USE: please heed relevant warnings and remarks. They are The ADU-17A is a mobile self-contained dental system marked as follows: that is used for endodontic and general dentistry applications.
  • Page 3: Introduction

    SAFETY PRECAUTIONS: Your new Aseptico Express Air Portable Dental System is the finest portable electric dental system available. The ADU-17A Aseptico accepts no liability for direct or consequential injury or features a handpiece control, 3-way air/water syringe, HVE and damage resulting from improper use, arising in particular through...
  • Page 4: Setting Up The Unit

    SETTING UP THE UNIT: FIG. 1 - ADU-17A Express Air HANDPIECE 3-WAY AIR/WATER SYRINGE HIGH VOLUME VACUUM (HVE) CLIP-ON INSTRUMENT HOLDER LOW VOLUME VACUUM (SALIVA EJECTOR) CASE HANDLE WASTE TANK TIE- DOWN RESEVOIR CONNECTOR WATER SUPPLY BOTTLE WASTE TANK COOLANT ON/OFF...
  • Page 5 Fig. 2a Fig. 2b Fig. 3 Clip-On Holder Handle 120V Indicator Saliva Ejector 3-Way 240V Indicator Syringe Voltage Selector Module Handpiece Attach a sterile handpiece to the ISO Type B (4-Line) Fig. 2c Fig. 2d handpiece connector and place the handpiece in Holder (Fig.
  • Page 6: Operation Functions

    TURN CONNECTOR 1/4 TURN CLOCKWISE Fig. 5 ON/OFF SWITCH: VACUUM LINE WITH QUICK Turns the ADU-17A system On or Off. DISCONNECT AIR FOOT CONTROL: The handpiece only operates when the foot pedal is depressed. When the foot pedal is not being used, the vacuum and syringe remain operational.
  • Page 7: Operation

    CAUTION: CAVITRON WATER OUTLET: Some new ADU-17A compressor motors might require Provides water via standard 1/4” quick disconnect to a 2-week “break-in” when first used. As a precaution against stalling the compressor or possibly blowing the independent Cavitron or scaler units requiring a water supply.
  • Page 8: Sterilization & Maintenance

    CAUTION: Use only NON-foaming cleansers in the vaccum lines. SYRINGE TIPS The ADU-17A unit features a three-way air/water syringe with quick-change autoclavable tips. To remove a tip, press on the locking collar surrounding the tip socket and pull...
  • Page 9: Troubleshooting

    TROUBLESHOOTING: EXTENSION CORD RECOMMENDA- TIONS: Unit will not start Use only a 3-wire extension cord that has a 3-blade grounding Check system’s power connection. plug. Connect extension cord plug to a matching 3-slot receptacle. Ensure that the extension cord is in good condition Turn On/Off switch ON for operation.
  • Page 10: Repacking Instructions

    Note: For reliable grounding, connect toreceptacle marked “Hospital Grade”. IMPORTANT NOTE: When running the ADU-17A unit at 230VAC 50Hz, expect approximately 17% less vacuum and pressure volume due to the slower turning of the compressor. This device has been tested and found to comply with the emissions requirements CAUTION: of IEC 60601-1-2:2001-09.
  • Page 11: Warranty

    Handpiece - Air ninety (90) days from the date of return to Aseptico, whichever is later. This limited warranty applies only to the initial or first installation of the product or part.
  • Page 12 P.O. Box 1548 • Woodinville, WA 98072 8333 216th Street SE • Woodinville, WA 98072 (425) 487-3157 • (800) 426-5913 www.aseptico.com • info@aseptico.com P/N: 420966 Rev. G ECO 15498 PRINTED IN THE 04/2022 U.S.A.