Installing the PCI fan and air baffle

Installing the PCI fan and air baffle
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If needed, disconnect any system cables that might be blocking access to the bottom side of the drive cage.
8. Install the PCI fan:
a. Align the spool on the chassis wall with the notches on the fan (callout 1).
b. Install the fan screws (callout 2).
Installing the PCI fan and air baffle