  • Page 1 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide Part Number: 30-0602ED3E-001 Published: March 2022 Edition: 1...
  • Page 2 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide Abstract Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products with hazardous energy levels, and are familiar with the weight and stability precautions for rack installations.
  • Page 3 Table of contents Table of contents Illustrated parts catalog Mechanical components Front bezel spare part Drive blank spare parts Miscellaneous blank spare parts Miscellaneous plastic spare parts System components Power supply spare part Power distribution board spare part Drive backplane spare parts DIMM spare parts System battery spare part Processor spare parts...
  • Page 4 Remove the server from the rack Remove the access panel Remove the air baffle Remove the PCI blank retainer Remove a media drive Power up the server Removing and replacing the front bezel Drive replacement Removing and replacing a non-hot-plug LFF SATA drive Removing and replacing a hot-plug LFF SAS or SATA drive Removing and replacing a hot-plug SFF SAS or SATA drive Drive backplane replacement...
  • Page 5 Removing and replacing the M.2 SATA SSD add‑in card Removing and replacing the M.2 SATA SSD from the add‑in card HPE NS204i-p NVMe OS Boot Device replacement Removing and replacing the boot device Removing and replacing a boot device drive Relocating the M.2 drive retaining latches Removing and replacing an internal USB device Removing and replacing the iLO dedicated network port blank...
  • Page 6 BitLocker recovery key/password retention guidelines Cabling Cabling guidelines Storage cabling Drive power cabling Storage controller cabling 4 LFF non-hot-plug drive controller cabling 4 LFF / 8 SFF hot-plug drive controller cabling Energy pack cabling Storage controller backup power cabling Media device cabling LTO tape drive cabling RDX backup system cabling Optical drive cabling...
  • Page 7: Illustrated Parts Catalog

    Description Description Media bay blank spare part Front bezel spare part SFF drive blank spare part LFF drive blank spare part Energy pack holder spare part Air baffle spare part HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 8: Front Bezel Spare Part

    Customer self repair: Mandatory Mandatory Description Description Spare part number Spare part number Media bay blank 879518-001 iLO dedicated network port blank P07883-001 Serial port blank 878510-001 Power supply blank 775423-001 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 9: System Components

    System components System components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported spare parts information, see the Hewlett Packard Enterprise PartSurfer website: https://www.hpe.com/info/partssurfer https://www.hpe.com/info/partssurfer HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 10 For more information on the removal and replacement procedures, see Removing and replacing an LFF non-hot-plug drive. 4 LFF hot-plug drive backplane spare part 8 SFF hot-plug drive backplane spare part DIMM spare parts System battery spare part Heatsink spare parts Processor spare parts HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 11: Power Supply Spare Part

    For more information on the removal and replacement procedures, see Removing and replacing the power distribution board . Drive backplane spare parts Drive backplane spare parts Customer self repair: Mandatory Mandatory HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 12: Dimm Spare Parts

    Spare part number Intel Xeon E-2314, 2.8 GHz, 4C, 65 W P45373-001 Intel Xeon E-2324G, 3.1 GHz, 4C, 65 W P45374-001 Intel Xeon E-2334, 3.4 GHz, 4C, 65 W P45375-001 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 13: Heatsink Spare Parts

    Spare part number System board P48074-001 For more information on the removal and replacement procedures, see System board replacement. System fan spare part System fan spare part Customer self repair: Mandatory Mandatory HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 14 Spare part number 4 LFF non-hot-plug drive cable spare kit, includes: P07483-001 Drive power extension cable 4 LFF non-hot-plug drive SATA cable 4 LFF/8 SFF hot-plug drive SATA cable spare P07484-001 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 15: Server Options

    Server options Server options Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported spare parts information, see the Hewlett Packard Enterprise PartSurfer website: https://www.hpe.com/info/partssurfer https://www.hpe.com/info/partssurfer HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 16 Type-p storage controller spare parts M.2 SATA SSD add-in card spare part For more information on the removal and replacement procedures, see Removing and replacing the M.2 SATA SSD add-in card. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 17: Pci Fan Spare Part

    For more information on the removal and replacement procedures, see Removing and replacing the energy pack . HPE NS204i-p NVMe OS Boot Device NS204i-p NVMe OS Boot Device spare parts spare parts Customer self repair: Mandatory Mandatory HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 18: Storage Controller Spare Parts

    For more information on the removal and replacement procedures, see Removing and replacing the M.2 SATA SSD add‑in card . iLO-M.2-serial module spare part iLO-M.2-serial module spare part Customer self repair: Mandatory Mandatory HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 19: Serial Port Cable Spare Part

    Spare part number 4 LFF / 8 SFF hot-plug drive standup controller Mini‑SAS cable 878327-001 LTO/RDX power extension cable spare part LTO/RDX power extension cable spare part Customer self repair: Mandatory Mandatory HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 20: Customer Self Repair

    Pour que la garantie puisse s'appliquer, Hewlett Packard Enterprise exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 21: Riparazione Da Parte Del Cliente

    Packard Enterprise dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt: Zwingend—Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den Austausch dieser Teile von Zwingend HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 22: Parts-Only Warranty Service (Garantieservice Ausschließlich Für Teile)

    Para obtener más información acerca del programa de Reparaciones del propio cliente de Hewlett Packard Enterprise, póngase en contacto con su proveedor de servicios local. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 23: Servicio De Garantía Exclusivo De Componentes

    OBSERVAÇÃO garantia do cliente, a Hewlett Packard Enterprise exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 24: Serviço De Garantia Apenas Para Peças

    No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a Hewlett Packard Enterprise substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 25 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 26 HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 27: Removal And Replacement Procedures

    Safety considerations Safety considerations Before performing service procedures, review all the safety information. Electrostatic discharge Symbols on equipment Rack warnings and cautions Server warnings and cautions Electrostatic discharge Electrostatic discharge HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 28: Symbols On Equipment

    This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 29 Hazardous moving parts. Keep away from moving fan blades. To reduce the risk of injury from a hot component, allow the surface to cool before touching. These symbols on power supplies or systems indicate that the equipment is supplied by multiple sources of power. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 30: Rack Warnings And Cautions

    Rack warnings and cautions Rack warnings and cautions WARNING: WARNING: When all components are removed, the server weighs 10.40 kg (22.93 lb). When all components are installed, the server HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 31: Server Warnings And Cautions

    AC power is removed. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components WARNING: HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 32: Preparation Procedures

    Remove the front bezel Remove the front bezel Procedure Procedure 1. Unlock the front bezel. 2. Open the front bezel. 3. Pull the front bezel away from the chassis. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 33: Power Down The Server

    A fully populated chassis is heavy. Hewlett Packard Enterprise recommends removing the external chassis components before removing the server from the rack. Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available. Procedure Procedure HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 34 Loosen the server tray thumbscrews (callout 1). b. Grasp the tray notch and slide the server out of the rack (callout 2). 6. Remove the server from the tray. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 35: Remove The Access Panel

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 36: Remove The Air Baffle

    Remove the air baffle CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or CAUTION: blanks installed. Procedure Procedure 1. Power down the server. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 37 6. Remove the air baffle: a. Lift the front end of the baffle from the chassis (callout 1). b. Remove the baffle tabs from its rear chassis slots (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 38: Remove The Pci Blank Retainer

    2. Slide the retainer up, and then remove it from the chassis. Remove a media drive Remove a media drive For better access to internal components, some procedures require the removal of the media drives. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 39 RDX drive power and USB cables Optical drive SATA-power Y-cable 8. Pull and hold the drive release latch (callout 1), and then slide the media drive out of the bay (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 40: Power Up The Server

    Removing and replacing the front bezel Removing and replacing the front bezel Procedure Procedure 1. Unlock the front bezel. 2. Open the front bezel. 3. Pull the front bezel away from the chassis. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 41: Drive Replacement

    4. Disconnect all peripheral cables from the server. 5. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 42 6. Remove the front bezel . 7. Remove the access panel . 8. Disconnect the drive power and SATA cables. 9. Remove the non-hot-plug drive cage. 10. Remove the non-hot-plug drive. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 43 1. Back up all server data on the drive. 2. Remove the front bezel . 3. Observe the drive LED status and determine if the drive can be removed. 4. Remove the drive. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 44 1. Back up all server data on the drive. 2. Remove the front bezel . 3. Observe the drive LED status and determine if the drive can be removed. 4. Remove the drive. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 45 Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Disconnect all peripheral cables from the server. 4. Do one of the following: HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 46 7. Remove the access panel . 8. Disconnect the drive power and onboard SATA cables. 9. Remove the 4 LFF hot-plug drive cage. 10. Remove the 4 LFF hot-plug drive backplane. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 47 3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 48 7. Remove the access panel . 8. Disconnect the drive power and onboard SATA cables. 9. Remove the 8 SFF hot-plug drive cage. 10. Remove the 8 SFF hot-plug drive backplane. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 49: Power Supply Replacement

    Verify that all power supplies have the same part number and label color. Removing and replacing a Flexible Slot power supply Removing and replacing a Flexible Slot power supply HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 50 Disconnect the power cord from the power supply. 2. Remove the power supply: a. Release the power cord from the strain relief strap. b. Disconnect the power cord from the power supply. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 51: Removing And Replacing The Non-Hot-Plug Power Supply

    Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available. WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply and the power supply blank WARNING: to cool before touching them. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 52 8. Remove the non-hot-plug power supply: a. Remove the power supply screws (callout 1). b. Press and hold the release latch (callout 2), and then remove the power supply (callout 3). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 53: Removing And Replacing The Power Distribution Board

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 54 6. If installed, remove all media drives . 7. Remove all power supplies . 8. Disconnect the RPS cables . 9. Remove the RPS cage. 10. Remove the power distribution board. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 55: Removing And Replacing The Power Supply Blank

    Removing and replacing drive blanks CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated CAUTION: with either a component or a blank. Procedure Procedure HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 56: Removing And Replacing A Sas Lto Tape Drive

    Removing and replacing a USB RDX docking station Removing and replacing an optical drive Removing and replacing a SAS LTO tape drive Removing and replacing a SAS LTO tape drive HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 57 6. Remove the access panel . 7. Disconnect the drive power and SAS cables . 8. Pull up and hold the release latch (callout 1), and then remove the LTO tape drive (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 58 3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 59: Removing And Replacing An Optical Drive

    8. Pull up and hold the release latch (callout 1), and then remove the RDX docking station (callout 2). To replace the component, reverse the removal procedure. Removing and replacing an optical drive Removing and replacing an optical drive HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 60 6. Remove the access panel . 7. Disconnect the power and SATA cables . 8. Pull up and hold the release latch (callout 1), and then remove the optical drive assembly (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 61 4. Remove the front bezel . 5. Press and hold the latch (callout 1), and then pull out the blank from the bay (callout 2). To replace the component, reverse the removal procedure. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 62: Removing And Replacing The Air Baffle

    6. Remove the air baffle: a. Lift the front end of the baffle from the chassis (callout 1). b. Remove the baffle tabs from its rear chassis slots (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 63: Fan Replacement

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 64 9. Disconnect the PCI fan cable . 10. Remove the PCI fan: a. Remove the fan screws (callout 1). b. Remove the fan from the chassis (callout 2). To replace the component, reverse the removal procedure. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 65: Removing And Replacing The System Fan

    5. Remove the access panel . 6. Disconnect the system fan cable . 7. Remove the system fan: a. Remove the fan screws (callout 1). b. Remove the fan from the chassis (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 66 3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 67: Removing And Replacing A Dimm

    Press and hold the rear latch (callout 2), and then lift the rear end of the energy pack from the holder (callout 3). c. Remove the energy pack from the holder (callout 4). To replace the component, reverse the removal procedure. Removing and replacing a DIMM Removing and replacing a DIMM HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 68 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. If the server is in rack mode, remove the server from the rack . 5. Remove the access panel . 6. Remove the DIMM. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 69: Removing And Replacing The Energy Pack Holder

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 70 8. Remove the energy pack holders: a. Push the latches inwards to release the holders on the bottom of the chassis. b. Remove the energy pack holders from the chassis. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 71: Heatsink Replacement

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 72 Use a T-15 Torx screwdriver to loosen one pair of diagonally opposite screws, and then loosen the other pair of screws (callouts 2 and 3). c. Lift the heatsink away from the system board (callout 4). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 73: Installing The Heatsink

    1. Use an alcohol wipe to remove the existing thermal grease from the processor. Allow the alcohol to evaporate before continuing. 2. Remove the thermal interface protective cover from the new heatsink. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 74 Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws (callout 2 and 3). When using a torque screwdriver, apply 0.68 N⋅m (6.0 lbf-in) of torque to completely tighten the screws. c. Connect the heatsink fan cable (callout 4). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 75: Processor Replacement

    6. Connect all peripheral cables to the server. 7. Connect each power cord to the server. 8. Connect each power cord to the power source. 9. Power up the server . Processor replacement Processor replacement HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 76: Processor Cautions

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 77 Use a T-15 Torx screwdriver to loosen one pair of diagonally opposite screws, and then loosen the other pair of screws (callouts 2 and 3). c. Lift the heatsink away from the system board (callout 4). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 78 Push the processor locking lever down to unclip it, and then pivot it to the vertical position (callout 1). b. Open the processor load plate (callout 2). 10. Do not touch the socket contacts or the bottom of the processor. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 79 11. Hold the processor by the edges, and then lift it out of the socket. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 80: Installing The Processor

    T-15 Torx screwdriver or a torque screwdriver with T-15 drill bit 1.0 gm (0.5 ml) or two 0.5 gm (0.25 ml) of thermal grease Procedure Procedure 1. Do not touch the socket contacts or the bottom of the processor. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 81 The processor load plate and locking lever should close without resistance. Forcing to close these parts can damage the processor and the socket. This damage might require replacing the system board. 3. Close the processor load plate (callout 1), and then engage the processor locking lever (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 82 Position the heatsink on top of the processor, ensuring that it is properly seated before securing the screws (callout 1). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 83 8. Connect all peripheral cables to the server. 9. Connect each power cord to the server. 10. Connect each power cord to the power source. 11. Power up the server . HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 84 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. If the server is in rack mode, remove the server from the rack . 5. Remove the access panel . 6. If installed, remove the air baffle . HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 85: Removing And Replacing An M.2 Ssd

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 86 Removing and replacing the iLO-M.2-serial module Removing and replacing the iLO-M.2-serial module CAUTION: CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 87 7. If installed, disconnect the serial port cable from the module . 8. If installed, remove the M.2 SSD . 9. Remove the iLO-M.2-serial module: a. Remove the module stabilizer. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 88 M.2 SATA SSD option replacement M.2 SATA SSD option replacement Removing and replacing the M.2 SATA SSD add‑in card Removing and replacing the M.2 SATA SSD from the add‑in card HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 89 6. Remove the access panel . 7. If installed, remove the air baffle . 8. Disonnect the M.2 SATA SSD cable . 9. Remove the PCI blank retainer. 10. Remove the add-in card. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 90 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCIe slots have either an expansion slot cover or an expansion card installed. Prerequisites Prerequisites HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 91 6. Remove the access panel . 7. If installed, remove the air baffle . 8. Disonnect the M.2 SATA SSD cable . 9. Remove the PCI blank retainer. 10. Remove the add-in card. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 92 Removing and replacing the boot device Removing and replacing a boot device drive Relocating the M.2 drive retaining latches Removing and replacing the boot device Removing and replacing the boot device CAUTION: CAUTION: HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 93 If the server is in rack mode, remove the server from the rack . 6. Remove the access panel . 7. If installed, remove the air baffle . 8. Remove the PCI blank retainer. 9. Remove the boot device. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 94 CAUTION: CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive devices. To prevent damage, observe antistatic precautions. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 95 If the server is in rack mode, remove the server from the rack . 6. Remove the access panel . 7. If installed, remove the air baffle . 8. Remove the PCI blank retainer. 9. Remove the boot device. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 96 Relocating the M.2 drive retaining latches Relocating the M.2 drive retaining latches Procedure Procedure 1. If your spare kit includes an 80 mm replacement drive, remove the retaining latch from its current location. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 97: Removing And Replacing An Internal Usb Device

    1. Power down the server. 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Disconnect all peripheral cables from the server. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 98 Removing and replacing the iLO dedicated network port blank Removing and replacing the iLO dedicated network port blank Prerequisites Prerequisites Before you perform this procedure, make sure that you have a spudger or any small prying tool available. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 99: Removing And Replacing The Serial Port Blank

    4. Remove the serial port blank: a. Use a plastic spudger to pry the blank from the chassis (callout 1). b. Remove the blank (callout 2). Retain the blank for future use. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 100: Removing And Replacing The Front I/O Assembly

    3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 101 9. Remove the ambient temperature sensor cable from the clips. 10. Press the front I/O bracket on both the ends from inside of the chassis (callout 1), and then remove the front I/O bracket (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 102 Use a plastic spudger to pry both sides of the I/O assembly holder (callout 1), and then remove the holder from the I/O cable. b. Remove the front I/O cable. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 103 3. Disconnect all peripheral cables from the server. 4. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 104: Removing And Replacing The Serial Port Cable

    Removing and replacing the serial port cable Prerequisites Prerequisites Before you perform this procedure, make sure that you have a hex screwdriver available. Procedure Procedure 1. Power down the server. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 105 If the server is in rack mode, remove the server from the rack . 5. Remove the access panel . 6. Remove the serial port: a. Remove the hex screws (callout 1). b. Detach the serial port from the rear panel (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 106: System Battery Replacement

    Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water. Removing and replacing the system battery Removing and replacing the system battery HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 107 7. Locate the battery on the system board . 8. Remove the system battery: a. Use a small flat-bladed, nonconductive tool to press the battery latch (callout 1). b. Remove the system battery from the socket (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 108 Press the system battery down until it clicks into place (callout 2). 10. If removed, install the air baffle. 11. Install the access panel. 12. Do one of the following: Orient the server back in tower mode. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 109: System Board Replacement

    Before you perform this procedure, make sure that you have the following items available: T-15 Torx screwdriver Hex screwdriver—This tool is required only if the serial port cable is installed. Alcohol wipe HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 110 10. If installed, remove the following components: Internal USB device Type-p storage controller Energy pack Energy pack holders Serial port cable iLO-M.2-serial module 11. Allow the heatsink to cool. 12. Remove the heatsink: CAUTION: CAUTION: HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 111 14. Open the processor load plate: a. Push the processor locking lever down to unclip it, and then pivot it to the vertical position (callout 1). b. Open the processor load plate (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 112 15. Do not touch the socket contacts or the bottom of the processor. 16. Hold the processor by the edges, and then lift it out of the socket. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 113: Installing The System Board Assembly

    Before you perform this procedure, make sure that you have the following items available: T-15 Torx screwdriver or a torque screwdriver with T-15 drill bit Hex screwdriver—This tool is required only if the serial port cable is to be installed. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 114 3. Open the processor load plate: a. Push the processor locking lever down to unclip, and then lift it upwards (callout 1). b. Open the processor load plate (callout 2). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 115 THE PINS ON THE PROCESSOR SOCKET AND ON THE PROCESSOR ARE VERY FRAGILE AND EASILY DAMAGED. damage to them might require replacing the system board. 4. Do not touch the socket contacts or the bottom of the processor. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 116 Pin 1 indicator on the processor and the socket b. Lower the processor straight down, without tilting or sliding the processor in the socket. Make sure that the processor is properly seated in the socket. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 117 7. Close the processor load plate (callout 1), and then engage the processor locking lever (callout 2). 8. Apply new thermal grease to the processor in the pattern shown in the following image to ensure even distribution. Use the full contents of the thermal grease syringe. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 118 Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws (callout 2 and 3). When using a torque screwdriver, apply 0.68 N⋅m (6.0 lbf-in) of torque to completely tighten the screws. c. Connect the heatsink fan cable (callout 4). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 119 17. Power up the server . 18. Make sure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that the latest drivers are being used. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 120: Re-Entering The Server Serial Number And Product Id

    Daylight Savings Time—Select whether to enable DST in the system time setting. 10. To confirm and save the settings, press F12 F12. The server automatically reboots. The installation is complete. Troubleshooting Troubleshooting HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 121: Nmi Functionality

    For a list of supported operating systems, see the HPE Servers Support & Certification Matrices at www.hpe.com/support/Servers- www.hpe.com/support/Servers- Certification-Matrices. Certification-Matrices Configuring the initial setup of a server Configuring the initial setup of a server HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 122 Software RAID HPE SR Gen10 Plus Software RAID User Guide at https://www.hpe.com/support/SSC-SRGen10Plus-ug https://www.hpe.com/support/SSC-SRGen10Plus-ug User guides for the Intel Virtual RAID on CPU for HPE Gen10 Plus at https://www.hpe.com/support/IntelVROC-Gen10Plus- https://www.hpe.com/support/IntelVROC-Gen10Plus- docs docs HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 123: Monitoring Servers

    Monitoring servers To monitor To monitor Supported notifications Supported notifications Single server HPE iLO ( www.hpe.com/support/ilo-docs www.hpe.com/support/ilo-docs ) SNMP SNMP Redfish events Redfish events Email alerts Email alerts syslog syslog HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 124: Updating The Server

    HPE Server Performance Management and Tuning Guide at features. www.hpe.com/info/server-performance-management-tuning-en www.hpe.com/info/server-performance-management-tuning-en Obtain recommendations for resolving incorrect settings. HPE InfoSight for Servers ( www.hpe.com/info/infosight-servers- www.hpe.com/info/infosight-servers- docs ) docs Configuring security Configuring security HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 125: Component Identification

    038 ) intensive applications. Component identification Component identification This chapter describes the external and internal server features and components. Front panel components Front panel components LFF drive models LFF drive models HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 126: Sff Drive Model

    Media bay 1 supports a SATA optical drive, SAS LTO drive, or a USB RDX docking station. Media bay 2 supports a SATA optical drive or a USB RDX docking station. SFF drive model SFF drive model HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 127 If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use HPE iLO to review the system health status. Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 128: Front Panel Led Power Fault Codes

    Storage backplane 9 flashes Power supply 10 flashes PCIe expansion cards installed in riser board 11 flashes Chassis 12 flashes GPU card 13 flashes Rear panel components Rear panel components HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 129: Rear Panel Leds

    NIC 1 / iLO shared port (1 GbE) Video port Serial port (optional) Rear panel LEDs Rear panel LEDs Item Description Item Description Status Status Definition Definition Power supply Solid green The power supply is operating normally. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 130: System Board Components

    Solid green Network link No network link NIC/iLO status Solid green Linked to network Flashing green Network active No network activity System board components System board components Item Item Description Description HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 131: System Maintenance Switch Descriptions

    System maintenance switch descriptions System maintenance switch descriptions Position Position Default Default Function Function Off = iLO 5 security is enabled. On = iLO 5 security is disabled. Reserved Reserved Reserved HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 132: Dimm Slot Location

    DIMM. For more information about product features, specifications, options, configurations, and compatibility, see the HPE DDR4 SmartMemory QuickSpecs on the Hewlett Packard Enterprise website (https://www.hpe.com/support/DDR4SmartMemoryQS https://www.hpe.com/support/DDR4SmartMemoryQS). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 133: Drive Bay Numbering

    When a server is purchased without any drive installed, some drive bays might be empty while other drive bays might be populated with drive blanks. To maintain proper system cooling, do not operate the server without a drive or a drive blank installed. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 134 4 LFF hot-plug drive numbering In the 4 LFF hot-plug drive configuration: SAS and SATA drives are supported. Onboard connection for Intel VROC SATA RAID support is through the SATA ports 1–4. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 135 The LFF low-profile drive carrier supports hot-plug SAS and SATA drives . SFF basic drive carrier basic drive carrier The SFF basic drive carrier supports hot-plug SAS and SATA drives . HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 136 The drive is operation normally and has activity. flashes per second) The drive is not configured by a RAID controller or is a spare drive. PCIe4 slot description PCIe4 slot description HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 137: Pcie Expansion Slot Definitions

    PCIe expansion slot definitions PCIe expansion slot definitions IMPORTANT: If an Intel Pentium processor is installed, the data transfer rate (throughput) of the PCIe4 expansion slot IMPORTANT: 1 switches down to PCIe3 speed. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 138 HPE NS204i-p NVMe OS Boot Device NS204i-p NVMe OS Boot Device components components Item Item Description Description Drive bay 1 Drive bay 2 Thermal interface pad with removable liner M.2 drive retaining latches HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 139: Fan Numbering

    Off: Normal Flashing 1Hz: Drive predictive failure Bay 2 LED Amber: Drive failure Fan numbering Fan numbering Fan number Fan number Description Description PCI fan (optional) System fan Heatsink fan HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 140: Fan Mode Behavior

    Trusted Platform Module 2.0 guidelines Trusted Platform Module 2.0 guidelines CAUTION: CAUTION: Always observe the TPM guidelines in this section. Failure to follow these guidelines can cause hardware damage or HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 141: Cabling Guidelines

    The cable colors in the cabling diagrams used in this chapter are for illustration purposes only. Most of the system cables are black. Observe the following guidelines when working with system cables. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 142: Before Connecting Cables

    Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires of the cable or the pins on the port. If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 143: Storage Cabling

    Drive power cabling Drive power cabling 4 LFF non-hot plug drive power cabling from the non-hot-plug power supply 4 LFF non-hot plug drive power cabling from the non-hot-plug power supply HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 144 4 LFF non-hot plug drive power cabling from the Flexible Slot power supply Color Color Description Description Orange Drive power cable (NHP PWR, from the Flexible Slot power fan-out cable ) Blue SATA-power splitter cable HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 145 4 LFF / 8 SFF hot-plug drive cabling from the Flexible Slot power supply The orange cable in the following diagram is the drive power cable (BP PWR) from the Flexible Slot power fan-out cable . HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 146: Storage Controller Cabling

    4 LFF / 8 SFF hot-plug drive: Onboard SATA cabling 4 LFF / 8 SFF hot-plug drive: Onboard SATA cabling The onboard SATA cabling for the 4 LFF and 8 SFF drive configurations use a single Mini-SAS splitter cable. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 147 Onboard SATA port 1 Pink Onboard SATA port 4 Green Onboard SATA port 3 Black Onboard SATA port 2 4 LFF hot-plug drive: Type-p controller cabling 4 LFF hot-plug drive: Type-p controller cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 148: Storage Controller Backup Power Cabling

    Color Color Description Description Orange Port 1 Mini-SAS cable Blue Port 2 Mini-SAS cable Energy pack cabling Energy pack cabling Storage controller backup power cabling Storage controller backup power cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 149: Media Device Cabling

    RDX backup system drive cabling Optical drive cabling LTO tape drive cabling LTO tape drive cabling LTO tape drive cabling with non-hot-plug power supply LTO tape drive cabling with non-hot-plug power supply HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 150 LTO tape drive cabling with Flexible Slot power supply LTO tape drive cabling with Flexible Slot power supply Color Color Description Description Gold P4 / P2 connector of the Flexible Slot power fan-out cable HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 151 P9 / P10 connector of the non-hot-plug power supply fan-out cable Blue LTO/RDX power extension cable Gold RDX USB cable RDX backup system cabling with Flexible Slot power supply RDX backup system cabling with Flexible Slot power supply HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 152: Optical Drive Cabling

    P4 / P2 connector of the Flexible Slot power fan-out cable Blue RDX USB cable Optical drive cabling Optical drive cabling Optical drive cabling with non-hot-plug power supply Optical drive cabling with non-hot-plug power supply Color Color Description Description HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 153 ODD PWR connector of the Flexible Slot power fan-out cable Blue Power connector of the SATA-power Y-cable Gold SATA connector of the SATA-power Y-cable M.2 SATA SSD add-in card cabling M.2 SATA SSD add-in card cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 154: Fan Cabling

    Orange M.2 SATA SSD 1 cable Blue M.2 SATA SSD 2 cable Fan cabling Fan cabling PCI fan cabling System fan cabling Heatsink fan cabling PCI fan cabling PCI fan cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 155 System fan cabling System fan cabling Heatsink fan cabling Heatsink fan cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 156: Serial Port Cabling

    To prevent the serial port cable from blocking the system fan airflow, route the cable beneath the fan, and then secure the extra length of the cable in the serial port cable clip. Front I/O cabling Front I/O cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 157: Power Supply Cabling

    Power supply cabling Non-hot-plug power supply cabling Flexible Slot power supply cabling Non-hot-plug power supply cabling Non-hot-plug power supply cabling The gray cable in the following diagram is the power fan-out cable. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 158 Connection Connects to the optical drive Connects to the LTO/RDX power extension cable Connects to the LTO/RDX power extension cable Flexible Slot power supply cabling Flexible Slot power supply cabling HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 159 4-pin power supply cable Gold Flexible Slot power supply sideband cable Flexible Slot power fan-out cable connectors Flexible Slot power fan-out cable connectors Item Item Cable label Cable label Connection Connection HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 160: Environmental Specifications

    This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1,500 ft/min). Nonoperating 9144 m (30,000 ft) Maximum allowable altitude change rate is 457 m/min (1,500 ft/min). HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 161: Mechanical Specifications

    Hewlett Packard Enterprise website website. HPE 350 W Gold Non-hot-plug Power Supply (92% efficiency) HPE 350 W Gold Non-hot-plug Power Supply (92% efficiency) Specification Specification Value Value Input requirements Input requirements — HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 162 558 W at 240 VDC for China only BTUs per hour 1999 at 100 VAC 1912 at 200 VAC 1904 at 240 VDC for China only Power supply output Power supply output — HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 163: Support And Other Resources

    Remote support Warranty information Regulatory information Documentation feedback Accessing Hewlett Packard Enterprise Support Accessing Hewlett Packard Enterprise Support For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 164: Information To Collect

    Remote support is available with supported devices as part of your warranty or contractual support agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event notifications to Hewlett Packard Enterprise, which initiates a fast HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 165: Warranty Information

    For Hewlett Packard Enterprise product environmental and safety information and compliance data, including RoHS and REACH, see: https://www.hpe.com/info/ecodata https://www.hpe.com/info/ecodata For Hewlett Packard Enterprise environmental information, including company programs, product recycling, and energy efficiency, see: https://www.hpe.com/info/environment https://www.hpe.com/info/environment HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...
  • Page 166: Documentation Feedback

    Feedback button and icons (located at the bottom of an opened document) on the Hewlett Packard Enterprise Support Center portal (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc) to send any errors, suggestions, or comments. All document information is captured by the process. HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide...

Table of Contents