INVERTER UNIT INSPECTION
Remove the inverter unit (page 8-7).
Check for continuity between the terminals using a
tester with diode measuring function according to the
tables below.
• Set the tester to the
perform this inspection.
• The "no continuity" display varies on each tester.
When there is no continuity, the display shows the
same as it does when the tester is not used for
measurement (OL, OF, etc).
• Some testers have reverse polarity.
mark position and
(-) Tester probe
Connec-
tor
Con-
Terminal
nector
1
13
3
(+) Tester probe
Connec-
tor
Con-
Terminal
nector
1
13
3
Connec-
tor
Con-
Terminal
nector
10
1
GENERATOR/CHARGING SYSTEM
Unit: V
5
5
0.3 - 0.8
0.3 - 0.8
Unit: V
10
1
0.3 - 0.8
0.3 - 0.8
(-) Tester probe
10
2
3
0.3 - 0.8
0.3 - 0.8
Viewed from terminal side
Viewed from terminal side
Unit: V
4
0.3 - 0.8
8-27