A 3 Applications

The unit is designed for the mixing of all types of plaster, investment materials and silicones, under vacuum.
It is also suitable for special techniques in dental technology such as the hydration of models.
As the model is kept moist in a better way than when using a pressure-investing unit, the separating medium between the model and the
prosthesis does not peel off prematurely.

A 4 Preparing for installation

A 4.1 Unpacking/Transport

- Remove all packing materials, and set the unit on a firm and flat surface. Alternatively, use the included wall bracket to mount it on the
wall.
- Check the included accessories.
- Before moving the unit, ensure that the electrical supply is disconnected.
- When shipping the unit, pack it in a suitable container to prevent transport damage.

A 4.2 Installation / Storage

- Set the unit on its final place, horizontally level, or mount it on the wall.
- When wall mounting, ensure that the wall is capable of carrying the load. Remove the wall bracket from the unit and use it as a template
for drilling holes for 8 mm plugs. Leave at least 25 – 30 cm free space under the unit.
- Ensure that the working and operating areas are not cramped (observe unit dimensions).
- Do not set up outside!
- For long-term storage, protect the unit against dampness and dust.
- Install the following connections before putting the unit into operation:
1. An electrical socket compatible with the voltage of the unit.
2. Compressed air connection as follows:
- minimum diameter of air supply line 6 mm.
- provide a servicing unit.
- adjust the pressure reducer to constant pressure.
There is no danger of unwanted mixing, as the motor is first activated when the mixing bowl is secured on the flange under vacuum,
and a mixing time has also been set.
Before putting the unit into operation check if the security plate on the underside of the unit has been turned 90°, and projects
beyond the housing. Tighten the screws again to prevent unwanted movement.