universalblue Campana T 60 Instruction Manual page 39

Table of Contents

Advertisement

Available languages

Available languages

Fault
Light on, but
motor does
not work
Light does
not work,
motor does
not work
Oil leakage
Lights not
working
Insufficient
suction
The Cooker
hood
inclines
This appliance has a warranty of 2 years from the date of purchase,
considering the following notes:
 Guarantee is only valid showing the invoice or purchase ticket.
 Damage caused during transportation, negligence, incorrect
installation or installation, and external influences such as:
Possible Cause
Fan switch turned off
Fan switch failed
Motor failed
House fuses blown
Power cord loose or
disconnected
One way valve and the
outlet are not tightly
sealed
Leakage from the
connection of chimney
and cover
Broken bulbs
The distance between the
cooker hood and the gas
top is too far
The fixing screw not tight
enough
Solution
Select a fan switch
position
Contact service center
Contact service center
Reset/Replace fuses
Refit cord to power outlet
Switch power outlet on
Take down the one way
valve and seal with sealant
Take chimney down and
seal
Contact Service center
Refit the cooker hood to
the correct distance
Tighten the hanging screw
and make it horizontal
39