Emerson Machinery Health PR 9350 Operation Manual page 20

Linear displacement transducer
Table of Contents

Advertisement

Operation Manual
NC: 6110-00125
Accuracy
Linearity error at
PR 9350/01
PR 9350/02
PR 9350/04
PR 9350/06
PR 9350/08
PR 9350/12
Temperature influence
on measuring value
Nominal inductance (typical values A-C)
PR 9350/01
Tracing pin ...
... in middle position
... maximum displacement
... min displacement
... driven out
PR 9350/02
Tracing pin ...
... in middle position
... maximum displacement
... min displacement
... driven out
PR 9350/04
Tracing pin ...
... in middle position
... maximum displacement
... min displacement
... driven out
PR 9350/06
Tracing pin ...
... in middle position
... maximum displacement
... min displacement
... driven out
100% of measuring range
±1.5%
±3.5%
±2.5%
±2.0%
±2.0%
±1.5%
< 3%, within whole temperature range -35°C to +120°C
13 mH
12 mH
12 mH
5.0 mH
19 mH
17 mH
17 mH
9.2 mH
16 mH
15 mH
15 mH
7.8 mH
16 mH
14 mH
14 mH
7.8 mH
Technical Data
04.06.2014
60% of measuring range
±1.0%
±0.5%
±0.5%
±0.5%
±0.2%
±0.2%
18

Advertisement

Table of Contents
loading

Table of Contents