Quick Links

one probe, SD card real time data recorder
CO2, %RH, Temp., Dew point, Wet bulb
CO2 METER + HUMIDITY/Temp.
Model : CO2-9914SD
Your purchase of this CO2 METER ,+ HUMIDITY/Temp. with SD CARD DATA
RECORDER marks a step forward for you into the field of precision measurement.
Although this Meter is a complex and delicate instrument, its durable structure
developed. Please read the following instructions carefull yand always keep
this manual within easy reach.
OPERATION MANUAL
All manuals and user guides at all-guides.com

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics CO2-9914SD

  • Page 1 SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD Your purchase of this CO2 METER ,+ HUMIDITY/Temp. with SD CARD DATA RECORDER marks a step forward for you into the field of precision measurement.
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com TABLE OF CONTENTS 1. FEATURES......................2. SPECIFICATIONS....................... 2-1 General Specifications....................2-2 Electrical Specifications................ 4 3. FRONT PANEL DESCRIPTION................4 MEASURING PROCEDURE.................... 5. OTHER FUNCTION....................5-1 Data Hold........................5-2 Record ( Max./ Min. reading )..............10 5-3 LCD Backlight ON/OFF..................
  • Page 3: Features

    All manuals and user guides at all-guides.com 1. FEATURES * Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic analysis by themselves.
  • Page 4: Specifications

    All manuals and user guides at all-guides.com 2. SPECIFICATIONS 2-1 General Specifications Circuit Custom one-chip of microprocessor LSI circuit. Display LCD size : 52 mm x 38 mm (Dot Matrix) LCD with green backlight ( ON/OFF ). Measurement CO2 (Carbon dioxide ) Humidity Dew point Temp., Wet bulb Temp.
  • Page 5 All manuals and user guides at all-guides.com Data Hold Freeze the display reading. Memory Recall Maximum & Minimum value. Sampling Time Approx. 1 second. of Display Data Output RS 232/USB PC computer interface. Connect the optional RS232 cable UPCB-02 will get the RS232 plug. Connect the optional USB cable USB-01 will get the USB plug.
  • Page 6: Electrical Specifications

    All manuals and user guides at all-guides.com Accessories Instruction manual..............1 PC Included Hard carrying case, CA-08..........1 PC CO2 / Humidity probe..........1 PC Optional SD memory card ( 4 GB ) Accessories AC to DC 9V adapter. USB cable, USB-01. RS232 cable, UPCB-02.
  • Page 7 All manuals and user guides at all-guides.com Dew Point Temp. ( Humidity ) ℃ -25.3 ℃ to 48.9 ℃ Range 0.1 ℃ Resolution ℉ -13.5 ℉ to 120.1 ℉. Range 0.1 ℉. Resolution Remark : * Dew Point display value is calculated from the Humidity/Temp.
  • Page 8: Front Panel Description

    All manuals and user guides at all-guides.com 3. FRONT PANEL DESCRIPTION Fig. 1...
  • Page 9 All manuals and user guides at all-guides.com 3-1 Display 3-2 Power Button ( Backlight Button ) 3-3 Hold Button ( ESC Button ) 3-4 REC Button 3-5 Alarm Button ( ▲ Button ) 3-6 Function Button ( ▼ Button ) 3-7 Time Button ( SET Button, Sampling check ) 3-8 Logger Button ( Enter Button ) 3-9 Stand...
  • Page 10: Measuring Procedure

    All manuals and user guides at all-guides.com 4. MEASURING PROCEDURES Measuring consideration a. The meter can plug in the max. 1 probes at the same time. The thress prones are : CO2 & Humidity probe . (It can simultaneously measure two kinds of functions.) b.
  • Page 11 All manuals and user guides at all-guides.com 2) Power on the meter by pushing the "Power Button"(3-2, Fig. 1) 2 seconds. 3) Press and hold the " Function Button " ( 3-6, Fig. 1 ) into sequence to select the measuring function : At the same time test tow kinds of functions, and display show four functions reading.
  • Page 12: Other Function

    All manuals and user guides at all-guides.com 5. OTHER FUNCTION 5-1 Data Hold During the measurement, press the " Hold Button " ( 3-3, Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol. Press the "...
  • Page 13: Datalogger

    All manuals and user guides at all-guides.com 6. DATALOGGER 6-1 Preparation before execute datalogger function a. Insert the SD card ≦ * It recommend use memory card 4 GB. Prepare a " SD memory card " ( 1 GB to 16 GB, optional ), insert the SD card into the "...
  • Page 14: Auto Datalogger ( Set Sampling Time ≧ 1 Second )

    All manuals and user guides at all-guides.com ≧ 6-2 Auto Datalogger ( Set sampling time 1 second ) a. Start the datalogger Press the " Logger Button ( 3-8, Fig. 1 ) >2 second , the LCD will show the text " Scan card ", then press the " Logger Button " ( 3-8, Fig.
  • Page 15: Manual Datalogger ( Set Sampling Time = 0 Second )

    All manuals and user guides at all-guides.com 6-3 Manual Datalogger ( Set sampling time = 0 second ) a. Set sampling time is to 0 second Press the " Logger Button ( 3-8, Fig. 1 ) >2 second , the LCD will show the text "...
  • Page 16: Check Sampling Time Information

    All manuals and user guides at all-guides.com 2) Then the LCD will present the Sampling time information of second unit. in the Display , as shown below. 6-6 SD Card Data structure 1) When the SD card is used into the meter, the SD card When the first time, the SD card is used into the meter, the SD card will generate a route : C2A01...
  • Page 17: Saving Data From The Sd Card To The Computer

    All manuals and user guides at all-guides.com 7. Saving data from the SD card to the computer ( EXCEL software ) 1) After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-19, Fig. 1 ). 2) Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the "...
  • Page 18 All manuals and user guides at all-guides.com...
  • Page 19: Advanced Setting

    All manuals and user guides at all-guides.com 8. ADVANCED SETTING Under do not execute the Datalogger function, press the " SET Button " ( 3-7, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode. then press the "...
  • Page 20 All manuals and user guides at all-guides.com General advanced setting 8-1 SD memory card Format When the lower display show " Sd F " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-6, Fig.
  • Page 21 All manuals and user guides at all-guides.com Remark : After the time value is setting, the internal clock will run precisely even Power off if the battery is under normal condition ( No low battery power ). 8-3 Set sampling time ( Hour/Minute/Second ) When the upper display show "...
  • Page 22 All manuals and user guides at all-guides.com 8-5 Set beeper sound ON/OFF When the lower display show " bEEP " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-6, Fig. 1 ) to select the upper value to " YES " or "...
  • Page 23 All manuals and user guides at all-guides.com ℃ ℉ 8-7 Select the Temp. unit to When the lower display show " t-CF " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-6, Fig.
  • Page 24: Power Supply From Dc Adapter

    All manuals and user guides at all-guides.com Special advanced setting ( only available for the CO2 function ) 8-10 Set the CO2 hight compensation value ( meters ) When the lower display show " meter ALTITUDE " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-6, Fig.
  • Page 25: System Reset

    All manuals and user guides at all-guides.com 2) Loose the screws of the " Battery Cover " ( 3-11, Fig. 1 ) and take away the " Battery Cover " from the instrument and remove the battery. 3) Replace with DC 1.5 V battery ( UM3, AA, Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.
  • Page 26 All manuals and user guides at all-guides.com The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : Start Word When send the %RH data ( probe 1 ) = 1 When send the Temp./%RH.
  • Page 27: Patent

    All manuals and user guides at all-guides.com 13. PATENT The meter ( SD card structure ) already get patent or patent pending in following countries : Germany Nr. 20 2008 016 337.4 JAPAN 3151214 CHINA ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 151211-CO29914SD...