Summary of Contents for Lutron Electronics UVC-254SD

  • Page 1 SD card real time datalogger + Type K/J thermometer UVC LIGHT METER Model : UVC-254SD Your purchase of this UVC LIGHT METER with SD CARD DATALOGGER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure developed.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES................1 2. SPECIFICATIONS..............2 3. FRONT PANEL DESCRIPTION............. 6 3-1 Display................6 3-2 Power Button ( ESC, Backlight Button )........ 6 3-3 Hold Button ( Function, Next Button )........6 3-4 REC Button ( Enter Button )..........6 3-5 SET Button ( Button, Time check Button )......
  • Page 3: Features

    1. FEATURES * Short wave 254 nm ultra-violet irradiance measurement. Professional UVC light meter, used to measure the UVCirradiation value under the UVC light source. source. * Two ranges : 2 mW/cm^2, 20 mW/cm^2. * UVC Light sensor with cosine correction filter. * UVC function build Zero button.
  • Page 4 * SD card capacity : 1 GB to 16 GB. * LCD with green light backlight, easy reading. * Can default auto power off or manual power off. * Data hold, record max. and min. reading. * Microcomputer circuit, high accuracy. * Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
  • Page 5 Datalogger Auto 1 second to 3600 seconds Sampling Time @ Sampling time can set to 1 second, Setting range but memory data may loss. Manual Push the data logger button once will save data one time. @ Set the sampling time to 0 second.
  • Page 6 Power Supply Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent. DC 9V adapter input. ( AC/DC power adapter is optional ). Power Current Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx.
  • Page 7 UVC Light sensor spectum Type K/J thermometer Sensor Resolution Range Accuracy Type Type K 0.1 ℃ -50.0 to 1300.0 ℃ ± ( 0.2 % + 0.5 ℃ -50.1 to -100.0 ℃ ± ( 0.2 % + 1 ℃ 0.1 ℉ -58.0 to 2372.0 ℉...
  • Page 8: Display

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Power Button ( ESC, Backlight Button ) 3-3 Hold Button ( Function, Next Button ) 3-4 REC Button ( Enter Button ) 3-5 SET Button ( Button, Time check Button ) ▼...
  • Page 9: Function Selection/Measurement

    4. MEASURING PROCEDURE 4-1 Function selection/Measurement 1) Turn on the meter by pressing the " Power Button " ( 3-2, Fig. 1 ) momentarily. Pressing the " Power Button " ( 3-2, Fig. 1 ) continuously and > 2 seconds again will turn off the meter.
  • Page 10 UVC Light masurement a. Set the function to the UVC light meter, refer to page 7. b. Install the " UVC Probe Plug " ( 3-17, Fig. 1 ) into the " Probe Input Socket " ( 3-7, Fig. 1 ). c.
  • Page 11: Data Hold

    Type K/J thermometer a. Function select to " Type K/J thermometer " b. Not install the " Probe Plug " ( 3-17, Fig. 1 ) into the " Probe Input Socket " ( 3-7, Fig. 1 ). c. Plug the Thermocouple Temp. Probe ( Type K Temp. probe pr Type J Temp.
  • Page 12: Data Record ( Max./ Min. Reading )

    4-3 Data Record ( Max., Min. reading ) 1) The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig. 1 ) once to start the Data Record function and there will be a " REC. " symbol on the display. 2) With the "...
  • Page 13: Datalogger

    5. DATALOGGER 5-1 Preparation before execute datalogger function a. Insert the SD card Prepare a " SD memory card " ( 1 G to 16 G, optional ), insert the SD card into the " SD card socket " ( 3-9, Fig. 1). The front panel of the SD card should face against the the down case.
  • Page 14 5-2 Auto Datalogger ( Set sampling time 1 second ) ≧ a. Start the datalogger Press the " REC Button ( 3-4, Fig. 1 ) once , the LCD will show the text " REC ", then press the " Logger Button " ( 3-6, Fig.
  • Page 15: Manual Datalogger ( Set Sampling Time = 0 Second )

    5-3 Manual Datalogger ( Set sampling time = 0 second ) a. Set sampling time is to 0 second Press the " REC Button ( 3-4, Fig. 1 ) once , the LCD will show the text " REC ", then press the " Logger Button " ( 3-6, Fig.
  • Page 16: Sd Card Data Structure

    5-5 Check sampling time information During the normal measurement ( not execute the Datalogger ), If press " Sampling Button " ( 3-6, Fig. 1 ) once , the lower LCD display will present the Sampling time information in second unit. 5-6 SD Card Data structure 1) When the first time, the SD card is used into the meter, the SD card will generate a folder :...
  • Page 17: Saving Data From The Sd Card To The Computer

    6. Saving data from the SD card to the computer ( EXCEL software ) 1) After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-9, Fig. 1 ). 2) Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the "...
  • Page 18: Advanced Setting

    EXCEL graphic screen ( for example ) 7. ADVANCED SETTING Under do not execute the Datalogger function, press the " SET Button " ( 3-5, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode. then press the "...
  • Page 19: Set Clock Time ( Year/Month/Date, Hour/Minute/ Second )

    Remark : During execute the " Advanced Setting " function, if press " Esc Button " ( 3-2, Fig. 1 ) once will exit the " Advanced Setting " function, the LCD will return to normal screen. 7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second ) When the lower display show "...
  • Page 20: Decimal Point Of Sd Card Setting

    7-2 Decimal point of SD card setting The numerical data structure of SD card is default used the " . " as the decimal, for example "20.6" "1000.53" . But in certain countries ( Europe ...) is used the " , " as the decimal point, for example "...
  • Page 21 7-4 Set beeper sound ON/OFF When the lower display show " bEEP " 1) Use the " Button " ( 3-6, Fig. 1 ) or " Button " ▲ ▼ ( 3-5, Fig. 1 ) to select the upper value to " yES " or "...
  • Page 22: Set Sampling Time

    7-6 Select the Temp. unit to ℃ ℉ When the lower display show " t-CF " 1) Use the " Button " ( 3-6, Fig. 1 ) or " Button " ▲ ▼ ( 3-5, Fig. 1 ) to select the upper Display text to " C " or "...
  • Page 23: Power Supply From Dc Adapter

    2)If select the upper to " yES ", press the " Enter Button " ( 3-4, Fig. 1 ) once again, the Display will show text " yES Enter " to confirm again, if make sure to do the SD memory card format, then press " Enter Button " once will format the SD memory clear all the existing data that already saving into the SD card.
  • Page 24: System Reset

    10. SYSTEM RESET If the meter happen the troubles such as : CPU system is hold ( for example, the key button can not be operated... ). Then make the system RESET will fix the problem. The system RESET procedures will be either following method : During the power on, use a pin to press the "...
  • Page 25 Meter (9W 'D" Connector) Center Pin......Pin 4 (3.5 mm jack plug) Ground/shield.......Pin 2 2.2 K resistor Pin 5 The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : Start Word When send the upper display data = 1...
  • Page 26: Optional Type K Temp. Probe

    RS232 FORMAT : 9600, N, 8, 1 Baud rate 9600 Parity No parity Data bit no. 8 Data bits Stop bit 1 Stop bit 12. Optional Type K Temp. probe (Type K) TP-01 * Max. short-tern operating Temperature: 300 (572 ℃...
  • Page 27: Patent

    13. PATENT The meter ( SD card structure ) already get patent or patent pending in following countries : Germany Nr. 20 2008 016 337.4 JAPAN 3151214 CHINA ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 1111-UVC254SD...