BMR46 series PoL Regulators
BMR46 series PoL Regulators
Input 4.5-14 V, Output up to 50 A / 165 W
Input 4.5-14 V, Output up to 50 A / 165 W
Output Load Transient Response, Default Configuration
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
di/dt=2 A/µs, f
= 320 kHz, C
= 470 µF/10 mΩ
sw
O
Default configuration (DLC and default NLR)
Output Load Transient Response, DLC and No NLR
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
di/dt=2 A/µs, f
= 320 kHz, C
= 470 µF/10 mΩ
sw
O
DLC and no NLR
Output Load Transient Response, DLC and Optimized NLR
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
di/dt=2 A/µs, f
= 320 kHz, C
= 470 µF/10 mΩ
sw
O
DLC and optimized NLR
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
Technical Specification
Technical Specification
1/28701-BMR 464 Rev.B
1/28701-BMR 464 Rev.B
July 2019
July 2019
© Flex
© Flex
59