BMR46 series PoL Regulators
Input 4.5-14 V, Output up to 50 A / 165 W

Safety Specification

General information
Flex Power DC/DC converters and DC/DC regulators are
designed in accordance with the safety standards
IEC 62368-1, EN 62368-1 and UL 62368-1 Audio/video,
information and communication technology equipment -
Part 1: Safety requirements
IEC/EN/UL 62368-1 contains requirements to prevent injury
or damage due to the following hazards:
• Electrical shock
• Electrically-caused fire
• Injury caused by hazardous substances
• Mechanically-caused injury
• Skin burn
• Radiation-caused injury
On-board DC/DC converters, Power interface modules and
DC/DC regulators are defined as component power
supplies. As components they cannot fully comply with the
provisions of any safety requirements without "conditions of
acceptability". Clearance between conductors and between
conductive parts of the component power supply and
conductors on the board in the final product must meet the
applicable safety requirements. Certain conditions of
acceptability apply for component power supplies with
limited stand-off (see Mechanical Information for further
information). It is the responsibility of the installer to ensure
that the final product housing these components complies
with the requirements of all applicable safety standards and
regulations for the final product.
Component power supplies for general use shall comply
with the requirements in
IEC/EN/UL
related standards, e.g. IEEE 802.3af Power over Ethernet,
and ETS-300132-2 Power interface at the input to telecom
equipment, operated by direct current (dc) are based on
IEC/EN/UL 60950-1
with regards to safety.
Flex Power DC/DC converters, Power interface modules
and DC/DC regulators are UL 62368-1 recognized and
certified in accordance with EN 62368-1. The flammability
rating for all construction parts of the products meet
requirements for V-0 class material according to
IEC 60695-11-10, Fire hazard testing, test flames – 50 W
horizontal and vertical flame test methods.
62368-1. Product
Technical Specification
1/28701-BMR 464 Rev.B
© Flex
Non - isolated DC/DC regulators
The DC/DC regulator output is ES1 energy source if the
input source meets the requirements for ES1 according to
IEC/EN/UL 62368-1.
3