Download Print this page

Flex BMR464 Series Manual page 13

Pol regulators
Hide thumbs Also See for BMR464 Series:

Advertisement

Prepared (also subject responsible if other)
EAB/FJB/GM QLAANDR
Approved
EAB/FJB/GM (Ksenia Harrisen)
BMR46 series PoL Regulators
BMR46 series PoL Regulators
Input 4.5-14 V, Output up to 50 A / 165 W
Input 4.5-14 V, Output up to 50 A / 165 W
Typical Characteristics
Start-up and shut-down
Start-up by input source
Start-up enabled by connecting V
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
C
= 470 µF/10 mΩ, I
= 40 A
O
O
Start-up by CTRL signal
Start-up by enabling CTRL signal at:
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
C
= 470 µF/10 mΩ, I
= 40 A
O
O
Checked
(MICRF)
at:
Top trace: output voltage (0.5 V/div.).
I
Bottom trace: input voltage (5 V/div.).
Time scale: (20 ms/div.).
Top trace: output voltage (0.5 V/div.).
Bottom trace: CTRL signal (5 V/div.).
Time scale: (20 ms/div.).
Ericsson Internal
PRODUCT SPECIFICATION
No.
2/1301-BMR 464 Uen
Technical Specification
Technical Specification
Date
Rev
2014-05-02
C
1/28701-BMR 464 Rev.B
1/28701-BMR 464 Rev.B
© Flex
© Flex
BMR 464 0002, BMR 464 1002
Shut-down by input source
Shut-down enabled by disconnecting
V
at:
I
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
C
= 470 µF/10 mΩ, I
= 40 A
O
O
Shut-down by CTRL signal
Shut-down enabled by disconnecting
V
at:
I
T
= +25 °C, V
= 12 V, V
= 1.0 V
P1
I
O
C
= 470 µF/10 mΩ, I
= 40 A
O
O
10 (21)
Reference
July 2019
July 2019
Top trace: output voltage (0.5 V/div).
Bottom trace: input voltage (5 V/div.).
Time scale: (2 ms/div.).
Top trace: output voltage (0.5 V/div).
Bottom trace: CTRL signal (5 V/div.).
Time scale: (2 ms/div.).
13

Advertisement

loading