an external program will have the ability to exchange command and control data with the camera
sensor directly.
o Digital Format – Select the video resolution you would like to use on the connected camera
sensor. The selected value will be set to the camera sensor upon boot-up, unless the sensor is set
to Custom, in which case the encoder module will not communicate with the camera sensor (here
the user needs to ensure that the camera block is configured correctly so that it can work with the
encoder).
o Reset Sensor – Will trigger the reset line of the sensor
Digital Sensor Settings – This section exposes all camera sensor parameters available. These parameters
•
are set and saved to the camera block itself if possible. Note that these settings are only available if the
Sensor selection is set to something other than Custom.
o Use Transparent Port – Enable this feature to expose the camera sensor command and
control port to external systems via a transparent TCP connection. When enabled, a serial
port instance will be displayed and made configurable via the Serial Port configuration
section. The name of this serial port instance is displayed via the Transparent Port
Instance field.
Image Settings – This section exposes the camera sensor's image settings. These parameters are set and
•
saved to the camera block itself if possible. Note that these settings are only available if the Sensor
selection is set to something other than Custom.