5.3 Understanding LED Status

Status of the ATOMAS-MINI-DUAL is exposed via the on-board bi-color LED (Green/Red). The following
describes the system status LED mappings of the ATOMAS-MINI-DUAL:
Normal Operation:
Operating system boot up – LED is steady orange (max. 30 seconds)
Internal application startup – LED is flashing orange (2 second interval)
System ready – LED is steady green
Media streaming – LED is flashing green (1/2 second interval)
Special Operations:
Identify command received – LED is flashing orange/green
Reset to factory settings – LED is flashing rapidly red/green
Software watchdog is rebooting the appliance – LED is flashing rapidly red
Firmware update in progress – LED is flashing slowly red/green