Advertisement

Quick Links

ATOMAS-MINI-DUAL
User Manual
OEM Encoder Platform
Document Version 2.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATOMAS-MINI-DUAL and is the answer not in the manual?

Questions and answers

Summary of Contents for IONODES ATOMAS-MINI-DUAL

  • Page 1 ATOMAS-MINI-DUAL User Manual OEM Encoder Platform Document Version 2.3...
  • Page 2 The information in this publication is provided “as is” without warranty of any kind. The entire risk arising out of the use of this information remains with the recipient. In no event shall IONODES be liable for any direct, consequential, incidental, special, punitive, or other damages whatsoever (including without limitation, damages for loss of business profits, business interruption or loss of business information), even if IONODES has been advised of the possibility of such damages and whether in an action or contract or tort, including negligence.
  • Page 3: Table Of Contents

    ATOMAS-MINI-BOSON-ADAPT ..............................19 Board layout ....................................20 Connector Part Numbers ..............................20 System Configuration ..................................22 Initial Network Configuration .............................. 22 Using the ATOMAS-MINI-DUAL Web Management Application ................. 23 8.2.1 System Status ................................... 24 8.2.2 Configuration / System ..............................25 8.2.3...
  • Page 4 Live Viewer ....................................49 Security ......................................50 Maintenance ....................................51 8.6.1 Performing a Firmware Update ..........................52 8.6.2 Batch Firmware Update ..............................53 Annex A - Troubleshooting Guide ............................... 54 Annex B - Statement Limited Warranty ............................. 54 support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 5: About The Atomas-Mini-Dual

    1 About the ATOMAS-MINI-DUAL The ATOMAS-MINI-DUAL dual port OEM encoder module delivers high quality H.264 video encoding to the video surveillance market. It is an embedded, high-performance digital video OEM encoder module designed for integration into HD cameras or other video capture products.
  • Page 6: Parts List

    Note: The product serial number label helps our product support team identify your device and its factory configuration in the event that your IONODES product or its components require service. The label is attached to the underside of the PCBA.
  • Page 7: Hardware Integration

    3 Hardware Integration The ATOMAS-MINI-DUAL has been designed to allow for flexible hardware integration to existing or new product designs. The ATOMAS-MINI-DUAL proposes four (4) mounting holes for securing to your enclosure. In addition, a slight clearance around the board’s edge can also be used for extrusion-type enclosures.
  • Page 8: Atomas-Mini-Dual

    5 ATOMAS-MINI-DUAL 5.1 Board layout Figure 1 - ATOMAS-MINI-DUAL Top Side support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 9 Figure 2 - ATOMAS-MINI-DUAL Bottom Side Note: On the bottom side of the ATOMAS-MINI-DUAL, near the edge of the PCB, there is a small physical button labelled “SW1”. This button allows the user to perform a reset to factory default settings. In order to do that the user must press and hold the button until the status LED on the board changes to an alternating Red/Green pattern.
  • Page 10: Connector Part Numbers

    5.2 Connector Part Numbers ATOMAS-MINI-DUAL • o Common to all module versions J2 – MicroSD / SD Connector / MOLEX 0525591052 J3 – LVDS Video Interface / KEL USL00-30L J5 – Ethernet & Power IN / Hirose DF20F-20DP-1V(56) J6 – Comm, GPIO & Audio / Hirose DF20F-20DP-1V(56) o AR0 model only J1 –...
  • Page 11: J1 - Analog Video Interface

    RESERVED RESERVED Pr IN RESERVED RESERVED RESERVED Pb IN C IN Y IN Y IN CVBS IN Note: The RESERVED ports are for internal use by IONODES and should be left disconnected on production designs. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 12: J2 - Micro Sd / Sd Connector

    In order to use the micro SD / SD functionalities, make sure to have a 2GB to 64GB microSD / SD card of class 6 or above. You must also make sure the card is formatted in FAT32 or EXT3. support@ionodes.com | https://imaging.ionodes.com...
  • Page 13: J3 - Lvds Video Interface

    LVDS DATA0 + LVDS DATA0- CAM UART TX Connects to camera’s TxD CAM UART RX Connects to camera’s RxD DC OUT DC OUT DC OUT DC OUT DC OUT RESET OUT Reset: Low (GND), Normal: Open (1.8V) support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 14: J4 - Second Digital Video Interface

    BT656 FSYNC FLIR DATA EN Note: The Second Digital Video Interface is only available on the ATOMAS-MINI-DUAL-DC0 version. In order to connect a camera block via this interface an adapter board is required. Currently, the only supported camera blocks are the FLIR BOSON 320/640 (60 Hz version only).
  • Page 15: J5 - Ethernet And Power In

    J5 provides standard 4-wire network connectivity. You only need 4 wires for 10/100 Base-T network connection; please connect the appropriate network connection pins to your RJ45 connector or wiring. Network status LED pins are also accessible if needed. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 16: J6 - Comm, Gpio And Audio

    CON IN 2 AUDIO LINE IN RIGHT CON IN 1 AUDIO LINE IN LEFT Note: The first 4 pins of the J6 can either start with RS-485 configuration (in the ATOMAS-MINI-DUAL-AR0) or UART/CAN configuration (in the ATOMAS-MINI-DUAL-DC0). support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 17: Understanding Led Status

    5.3 Understanding LED Status Status of the ATOMAS-MINI-DUAL is exposed via the on-board bi-color LED (Green/Red). The following describes the system status LED mappings of the ATOMAS-MINI-DUAL: Normal Operation: Operating system boot up – LED is steady orange (max. 30 seconds) •...
  • Page 18: Atomas-Sdio

    6 ATOMAS-SDIO The ATOMAS-SDIO breakout card is an optional module offered by IONODES, which provides microSD storage support to your ATOMAS-MINI-DUAL module. The ATOMAS-SDIO module is provided as part of the ATOMAS-SDIO-KIT part number which also includes a flat flex cable required to connect the ATOMAS-SDIO to the ATOMAS-MINI-DUAL module.
  • Page 19: J2 - 10-Pin Microsd / Sd Connector

    TE CONNECTIVITY 1-1734839-0 Pin No. Name Comments DATA BIT 1 DATA BIT 0 CLOCK POWER 2.7V – 3.6V DC COMMAND LINE DATA BIT 3 DATA BIT 2 CARD DETECT WRITE PROTECT Not Connected 7 ATOMAS-MINI-BOSON-ADAPT support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 20: Board Layout

    The ATOMAS-MINI-BOSON-ADAPT module is a video interface add-on module, designed for use with the ATOMAS-MINI-DUAL encoder platform. This optional module provides a direct connection to FLIR BOSON 320/640 (60Hz variant) thermal camera on the secondary digital video input of the ATOMAS-MINI-DUAL. 7.1 Board layout...
  • Page 21 J1 – FLIR Connector / Hirose DF40HC-(4.0)-80DS-0.4V • J2 – KEL Connector (towards ATOMAS-MINI-DUAL ) / KEL USL00-30L • Note: The J2 connector on the ATOMAS-MINI-BOSON-ADAPT module is designed to mate with connector J4 of the ATOMAS-MINI-DUAL module. support@ionodes.com | https://imaging.ionodes.com...
  • Page 22: System Configuration

    8.1 Initial Network Configuration By factory default, the ATOMAS-MINI-DUAL is configured in DHCP. If you are not using a DHCP server it will automatically allocate itself an APIPA (Automatic Private IP Addressing) address in the range 169.254.0.1 to 169.254.255.254, with subnet mask 255.255.0.0.
  • Page 23: Using The Atomas-Mini-Dual Web Management Application

    8.2 Using the ATOMAS-MINI-DUAL Web Management Application When entering the web interface, you will be asked for a username and password. Upon first access to the web interface the user will need to choose a new password for the administrator account.
  • Page 24: System Status

    A link is provided for the older Silverlight-based web interface that is still needed for modifying some advanced settings. Once these features are migrated to the new HTML5-based interface, the older interface will not be required anymore. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 25: Configuration / System

    Under the Configuration section, select the System tab to perform the following operations: Specify a Device Name; this custom name can be used by third-party software to display a friendly name • for the device support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 26: Configuration / Network

    If your thermal shutdown thresholds are not correlated with the thermal performance of your cooling solution, the platform may experience unstable operation, so please use this feature very carefully and apply it in the field only after extensive qualification in the lab! 8.2.3 Configuration / Network support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 27 Host Name Configuration – Set the encoder’s network name. • Streaming – Set the MTU size for all media related RTP packets sent on the network; avoid changing this • setting unless absolutely necessary. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 28 Authentication mode – Basic or Digest Authentication for RTSP connections. o Send RTCP Reports – Enables the RTCP sender’s report, that is used to provide reception quality feedback between the sender and receiver of the video stream support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 29 Miscellaneous ports - Enable or disable various system ports used for auxiliary functionality (like • system logs for instance) support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 30 | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 31: Configuration / Imaging

    In custom mode, the camera sensor command and control will only be accessible via a transparent TCP connection over which support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 32 Image Settings – This section exposes the camera sensor’s image settings. These parameters are set and • saved to the camera block itself if possible. Note that these settings are only available if the Sensor selection is set to something other than Custom. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 33 Within the same OSD, two independent texts can be configured. You can have for instance the camera name plus the time/date. Please check “Custom Text Formats” for details on the available automatic (dynamic) text options. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 34 Privacy Zones – This section allows you to configure up to 16 privacy zones. Please note that the zones’ • positions are fixed. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 35 | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 36: Configuration / Video Input

    Under the Configuration section, select the Video Input tab to perform the following operations: General – This section allows you to enable/disable the currently selected video input, as well as • associate audio from one of the audio in sources support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 37 H.264 compression process. o Intra interval – Defines the GOP size o VBR aggressiveness is unique to IONODES encoders and proposes various levels (disabled to aggressive) of motion triggered rate control. The more aggressive the setting, the more variation motion will have on the rate control.
  • Page 38 The values refer to the encoders configured in previous sections of the web interface. o Destination IP: Address where to send the video stream. Please note that the destination can be a multicast group address. o Destination Port: Network port where to send the video stream. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 39 Once all the settings have been set, click on Save at the bottom of the page in order to apply them. The ATOMAS-MINI-DUAL then creates or updates the connection as needed. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 40 Enable Proportional Pan/Tilt Speed – Allows the encoder to automatically modify the Pan/Tilt Speed based on the current Zoom position (the further you Zoom In the lower the Pan/Tilt Speed) support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 41 (frame count, sensitivity, on/off thresholds, alarm on/off delay). Based on the applied settings, a red bar will show the current level of motion activity inside a specific region of interest. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 42 | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 43 2-Wire Command Delay – sets the command delay for cases where the serial connection to the PTZ controller is working in 2-wire mode JPEG Image Upload – This section allows you to configure JPEG Upload functionality. • support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 44: Configuration / Audio Input

    Configure audio input compression parameters for each of the audio inputs on the encoder • Configure point to point audio connections (up to three) for creating persistent audio streams from the • encoder to a network endpoint support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 45: Configuration / Audio Out

    Under the Configuration section, select the Audio Output tab to perform the following operations: Configure audio output parameters • Configure a point to point audio connection for receiving a persistent audio stream from a network • endpoint support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 46: Configuration / Serial Port

    8.2.8 Configuration / Serial Port Under the Configuration section, select the Serial Port tab to perform one of the following operations: support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 47 When in Custom sensor mode, this section will expose serial port settings to allow you to properly configure the serial port connection with your custom camera sensor. support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 48: Configuration / Integration

    Invert ONVIF H264 encoder profile - This will invert the profile number for the two H.264 profiles that • the encoder exposes to a VMS; for instance H.264_1 will actually be recognized by the VMS as Profile 2, while H.264_2 will become Profile 1 for the VMS 8.3 Peripherals support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 49: Live Viewer

    The ATOMAS-MINI-DUAL provides various digital I/O interfaces for control tasks purposes. The status of the input pins can be seen in the corresponding subsection. With regards to the output relay, clicking on the corresponding icon will trigger a change in its state (from open to closed or vice-versa).
  • Page 50: Security

    8.5 Security support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 51: Maintenance

    The Superuser role allows access to live and recorded clip viewing and changing any setting aside from the user accounts list. o The Administrator role allows access to viewing and changing any setting in the system. 8.6 Maintenance support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 52: Performing A Firmware Update

    (with or without including the network settings). You can also identify a specific unit (if you have multiple units of the same type in the same location) by flashing its status LED. 8.6.1 Performing a Firmware Update support@ionodes.com | https://imaging.ionodes.com | 1-450-696-1060...
  • Page 53: Batch Firmware Update

    5. Firmware update complete. (100%) 8.6.2 Batch Firmware Update In order to perform a batch update of multiple ATOMAS-MINI-DUAL devices to newer firmware versions you’ll need to use the ICT (IonConfigTool). The procedure is explained in detail in the ICT user manual. Please check our website for the latest version.
  • Page 54: Annex A - Troubleshooting Guide

    • o Validate the flex cable is properly connected into the ATOMAS-MINI-DUAL and into the camera o Verify that the video connectors on both the ATOMAS-MINI-DUAL as well as the camera block are not physically damaged No video is displayed in the GUI •...
  • Page 55 The warranty period for an ATOMAS-MINI-DUAL is a specified, fixed period commencing on date of billing by IONODES for the Product. If a valid proof of billing cannot be found, the warranty may be void by IONODES Inc. or measured from the date the ATOMAS-MINI-DUAL has shipped from an IONODES Depot center based on its serial number.
  • Page 56 ATOMAS-MINI-DUAL set–up and installation, will be provided WITHOUT WARRANTIES OF ANY KIND. For more information, please contact our technical support team: • Call: 450-696-1060 or 1-844-696-1060 (North America Toll Free) • Send an email to: support@IONODES.com...

Table of Contents