Ordering Procedure - Tyco DN40 Manual

Preaction system with model dv-5 deluge valve double interlock — electric/pneumatic actuation 1-1/2 thru 8 inch
Hide thumbs Also See for DN40:
Table of Contents

Advertisement

TFP1460
Ordering
Procedure
With reference to Table A on Page 16,
the following items must be ordered
separately:
• Deluge Valve
• Riser Check Valve
• Coupling (Deluge Valve to Riser
Check Valve)
• Double Interlock Preaction Trim
• Automatic System Air Supply
• Solenoid Valve
• Accessories
NOTE
1-1/2 inch (DN40) risers utilize a 2 inch
(DN50) Riser Check Valve in combina-
tion with the 1-1/2 inch (DN40) Model
DV-5 Deluge Valve.
Part Numbers for factory pre-trimmed
Model DV-5 Valves are provided in the
Price Book.
Replacement Trim Parts:
Specify: (description) for use with
Model DV-5 Deluge Valve, P/N (see
Figure 2A).
DELUGE VALVE (SELECT ONE)
P/N's are for American Standard Groove x Groove Connections, and Threaded Ports, For
other configurations refer to Technical Data Sheet TFP1305. Specify: (size) Model DV-5
groove x groove Deluge Valve, P/N (specify).
1-1/2 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RISER CHECK VALVE (SELECT ONE)
P/N's are for American Standard Grooved Connections. For other configurations refer to
Technical Data Sheet TFP950 for the groove x groove Model CV-1FR Riser Check Valve.
Specify: (size), Model CV-1FR groove x groove Riser Check Valve, P/N (specify). For 1-1/2
inch risers, use the 2 Inch Riser Check Valve.
2 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COUPLING (SELECT ONE)
P/N's are for American Standard Grooved Connections. For other configurations and
finishes refer to Technical Data Sheet TFP1830 and TFP1880. A coupling to attach the
Riser Check Valve to the outlet of the Deluge Valve must be separately ordered. Specify:
(Size), (Figure #), painted, (description), P/N (specify). For 1-1/2 inch risers, order an
additional Reducing Coupling for the outlet of the 2 inch Riser Check Valve.
2 x 1-1/2 Inch Figure 716 Painted Reducing Coupling . . . . . . . . . . . . . . . . . . . . . . .
2 Inch Figure 772 Painted Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Inch Figure 772 Painted Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Inch Figure 772 Painted Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Inch Figure 772 Painted Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Inch Figure 772 Painted Rigid Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DOUBLE INTERLOCK PREACTION TRIM (SELECT ONE)
Specify: (specify size and finish — galvanized is standard) Semi-Preassembled Double
Interlock Preaction System With Electric/Pneumatic Actuation Trim for Model DV-5 Deluge
Valves, P/N (specify).
1-1/2 & 2 Inch Galvanized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1/2 & 2 Inch Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Inch Galvanized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Inch Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4, 6 & 8 Inch Galvanized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4, 6 & 8 Inch Black. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOMATIC SYSTEM AIR SUPPLY (SELECT ONE)
A device capable of maintaining a nominal system air or nitrogen pressure per Graph A
must be separately ordered. Specify: (Specify model and description), P/N (specify).
Model AMD-1 Air Maintenance Device (TFP1221) . . . . . . . . . . . . . . . . . . . . . . . . . .
Model AMD-2 Air Maintenance Device (TFP1231) . . . . . . . . . . . . . . . . . . . . . . . . . .
Model AMD-3 Nitrogen Maintenance Device (TFP1241) . . . . . . . . . . . . . . . . . . . . .
SOLENOID VALVE (SELECT ONE)
A Solenoid Valve compatible with the anticipated maximum water supply pressure must
be ordered separately. Refer to Technical Data Sheet TFP2180 for other voltage ratings
and NEMA classifications. Specify: 24 VDC, NEMA 2, 4 and 4X, (specify 175 or 250 psi)
Solenoid Valve, P/N (specify).
175 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
250 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACCESSORIES (AS NEEDED)
Specify: (description), PN (specify).
600 PSI Water Pressure Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model WMA-1 Water Motor Alarm (TFP921) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TABLE A — ORDERING LIST
Page 15 of 16
P/N 52-477-1-919
P/N 52-477-1-910
P/N 52-477-1-912
P/N 52-477-1-913
P/N 52-477-1-915
P/N 52-477-1-916
P/N 59-590-1-020
P/N 59-590-1-030
P/N 59-590-1-040
P/N 59-590-1-060
P/N 59-590-1-080
P/N 7162015ES
P/N 77220ASC
P/N 77230ASC
P/N 77240ASC
P/N 77260ASC
P/N 77280ASC
P/N 52-478-2-127
P/N 52-478-1-127
P/N 52-478-2-124
P/N 52-478-1-124
P/N 52-478-2-121
P/N 52-478-1-121
P/N 52-324-2-002
P/N 52-326-2-001
P/N 52-328-2-001
P/N 52-287-1-024
P/N 52-287-1-124
P/N 92-343-1-004
P/N 52-630-1-001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dn200

Table of Contents