Siemens SITRANS FUS060 Operating Instructions Manual page 62

Ultrasonic flowmeters with profibus pa
Hide thumbs Also See for SITRANS FUS060:
Table of Contents

Advertisement

Functions
7.4 Device outputs (menu 4)
Signal type (menu 4.2.2)
In this menu the signal type of the digital output 1 can be configured. Only passive signals with
selectable signal logic (positive or negative) are available for this output, i. e. the output acts as
a switch and may have to be connected to an external supply (observe the current limit,
see Technical specifications (Page 79)).
Figure 7-4
Signals with positive and negative logic can be generated (positive or negative pulses).
The figure below illustrates the setting options.
I[mA]
I[mA]
Figure 7-5
Pulse value (menu 4.2.3)
There are two parameters to be set for the pulse output in this menu:
• Unit
The physical unit (unit/pulse).
• Pulse rate
Number of mass/volume units per pulse.
62
5 (+)
I
T
2
6 (-)
Counter
External supply
Passive signals
Passive-positive
Passive-negative
Transistor T
conductive
2
Transistor T
disabled
2
Time
Signal types for digital output 1
4 7 8 3 5
U
SITRANS FUS060 with PROFIBUS PA
Operating Instructions, 09/2021, A5E02225054-AD