netvox R718PA5 User Manual

netvox R718PA5 User Manual

Wireless no2 sensor
Hide thumbs Also See for R718PA5:

Advertisement

Quick Links

Model: R718PA5
Wireless NO2 Sensor
Wireless NO2 Sensor
R718PA5
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall
be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written
permission of NETVOX Technology. The specifications are subject to change without prior notice.

Advertisement

Table of Contents
loading

Summary of Contents for netvox R718PA5

  • Page 1 User Manual Copyright©Netvox Technology Co., Ltd. This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction....................2 2. Appearance ....................3 3. Main Feature ....................3 4. Set Up Instruction ..................4 5. Data Report ....................5 5.1 Example of ReportDataCmd .............. 5 5.2 Example of ConfigureCmd ..............6 6. Installation ....................7 7.
  • Page 3: Introduction

    R718PA5 is a Class A device based on the LoRaWAN protocol of Netvox and is compatible with LoRaWAN protocol. R718PA5 can be connected with an NO2 sensor (RS485), and report the NO2 concentration collected by the device to the corresponding gateway. The device is compatible with LoRaWAN protocol.
  • Page 4: Appearance

    2. Appearance NO2 Sensor Indicator Function Key 3. Main Feature  Adopt SX1276 wireless communication module  12V DC power supply  NO2 sensor detection  The base is attached with a magnet that can be attached to a ferromagnetic material object ...
  • Page 5: Set Up Instruction

    4. Set Up Instruction On/Off Power On DC12V adapter Turn On DC12V power supply, the green indicator flashing once means turn on successfully. Turn Off (Restore to factory setting) Press and hold the function key for 5 seconds, and the green indicator flashes 20 times Power Off Remove DC12V adapter 1.
  • Page 6: Data Report

    Note: 1. Report interval is based on the factory default. 2. R718PA5 reports the NO2 concentration value. 3. The device reported data parsing please refer to Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index 5.1 Example of ReportDataCmd FPort:0x06...
  • Page 7: Example Of Configurecmd

    (2bytes Unit: s) (2bytes Unit: s) (5Bytes, Fixed 0x00) (1) Configure R718PA5 device parameter MaxTime = 1min (The MinTime configuration is useless, but it needs to be set greater than 0 because of the software limitation.) Downlink: 0157000A003C0000000000 Device Return:...
  • Page 8: Installation

    6. Installation 1. R718PA5 has the built-in magnet (as the figure below) 2. R718PA5 regularly reports data that is NO2 which can be attached to the surface of an iron object during concentration according to MaxTime. installation, which is convenient and quick.
  • Page 9: Important Maintenance Instruction

    7. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.