Disassembly and Reassembly > Disassembly
(23) Lens Frame, Lens Unit, Cushion and Crystal Filter
1) Disconnect the fl at cable.
2) Remove the screw [C].
3) Turn the GSL-3M circuit board (e) up in the
direction of the arrow.
4) Remove the two screws [D].
5) Remove the screw [C] and then remove the
lens frame (a).
6) Remove the two screws [F] and then remove
the cushion (c) and the crystal fi lter (d) from
the lens unit (b).
Note:
1) The lens unit and crystal fi lter are precision
components: Take great care when handling
them. Adherence of any dust, foreign object,
fi ngerprint, etc. to them, or any scratches or
impact, could cause a fault.
2) Never use metal tweezers to handle the
crystal fi lter: Doing so could damage it.
Cautions during disassembly and reassembly:
Take care with the orientation of crystal fi lter
when assembling it: Incorrect orientation of
the crystal fi lter could cause a fault.
(24) CCD Image Sensor and GSL-3M Circuit Board
1) Unsolder the 26 points at the CCD image
sensor (a) terminal on GSL-3M circuit board
(b).
Note:
The CCD image sensor is a precision
component: Take great care when handling it.
Adherence of any dust, foreign object,
fi ngerprint, etc. to it, or any scratches or
impact, could cause a fault.
[For DZ-HS303A/ GX3300A]
(a) Lens frame
(b) Lens unit
(c) Cushion
(d) Crystal fi lter
(e) GSL-3M circuit board
[C] M1.7×3 (Silver)
[D] M1.7×4 (Black)
[F] M1.7×5 (Silver)
5) [C]
(a)
4) [D]
[For DZ-HS303A/ GX3300A]
(a) CCD image sensor
(b) GSL-3M circuit board
1)
(a)
5 - 22
2) [C]
6) [F]
6) [F]
(c)
(d)
(e)
1)
(b)
Fig. 5-3-23
(b)
Fig. 5-3-24
3)