6. When complete, reverse steps to reinstall the bridge. NOTE: The black motor wires go on the
top terminal, the white on the bottom. The pump solenoid valve wires go in positions 1 and 4 of
the 6-pin connector C-2; the vent vacuum-breaker solenoid valve wires go in positions 2 and 5;
the red/black heater tape wires go into position 3 and the violet/white wires go into position 6
(see illustration on the following page).
7. Disconnect any heater tape wiring from connectors and remove heater tape. Motor and pump can
be separated and removed individually or as one unit.
8. Reconnect the unit to the electrical power supply, and verify that the pump is functioning
correctly (i.e., when a filter handle is placed in the ON position, the motor should start and there
should be strong suction at the intake fitting and outflow at the rear flush port.)
9. When proper operation has been verified, reinstall the back panels and the filter pan and lid.
10. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply to
return the fryer to service.

1.9.3 Replacing the Filter Transformer or Filter Relay

Disconnect the fryer from the electrical power supply. Remove the left controller from the fryer to
expose the interior of the left component box. The filter transformer and relay are behind the
controller on a single fryer or just right of the filter in a bank of two or more. The filter transformer
and relay are located as shown in the illustration below. .