Layout - Festo EduTrainer 576309 Operating Instructions Manual

Motor switches
Table of Contents

Advertisement

Available languages

Available languages

®
Motor Switches EduTrainer

9 Layout

No.
Description
On/off switch – 4-pole switching of input voltage (on/off). Continuous switching current: 16 A
1
Reversing switch – two phases are reversed when the switch is turned back and forth between positions "1" and "2".
2
Connecting a 3-phase asynchronous motor results in reversal of the direction of rotation. Continuous switching
current: 16 A
Star-delta switch – if a corresponding 3-phase asynchronous motor has been connected, this switch allows for star-delta
3
starting. Continuous switching current: 16 A
4/5
Output sockets of the star-delta switch – for connecting a 3-phase asynchronous motor.
6
Input sockets of the star-delta switch
7
Output sockets of the reversing switch
8
Input sockets of the reversing switch
9
Output sockets of the on/off switch
10
Input sockets of the on/off switch
11
Protective earth terminal – must be connected to the protective conductor system before operation.
The contact is designed as a PE+ connection at the factory.