Available languages

7 Technical data

Technical data
Input voltage
Input frequency
Maximum switching current:
Protection class
Overvoltage category
Degree of contamination
Electrical connections
Protective grounding terminal
Operating temperature range
Max. relative humidity
Protection
Device operation
Dimensions (H x W x D in mm)
Certifications
CE marking

8 Description

The Motor Switches EduTrainer
The motor can be controlled in various operating modes with the:
On/off switch
Reversing switch
Star-delta switch
The three switches can be connected in series with the help of safety jumper plugs, in order to implement all
switching functions in a single setup.
© Festo Didactic 762418
3x (230/400) V AC ±10%
50 ... 60 Hz
16 A (AC)
1, operation with protective earthing
II, operation in building installations
2, laboratory environment
Safety laboratory cables per EN 61010-031, min. conductor cross-section: 1 sq. mm
PE+ contact
5 ... 40° C / 100%
80%
IP 30 (not attached to the mounting frame)
Use only indoors, max. altitude: 2000 m above sea level
297 mm x 266 mm x 95 mm
Low-voltage directive
RoHS directive
®
is used for simple control of 3-phase motors.
®
Motor Switches EduTrainer
25