4.3 SCPI Subsystem Commands
Subsystem commands control all Z
+
7.12 in Z
series User Manual. Short list of Z
SCPI Command
ABORt
DISPlay
[:WINDow]:STATe <bool>
[:WINDow]:FLASh <bool>
GLOBal
:CURRent
:[AMPLitude] <NRf+>
:VOLTage
:[AMPLitude] <NRf+>
:OUTPut:STATe <bool>
*RCL {1|2|3|4}
*RST
*SAV {1|2|3|4}
INITiate
[:IMMediate]
:CONTinuous <bool>
INSTrument
:COUPle ALL|NONE
:NSELect <NRf>
MEASure
:CURRent[:DC]?
:VOLTage[:DC]?
:POWer[:DC]?
OUTPut
[:STATe] <bool>
:PON
[:STATe] <bool>
:PROTection
:CLEar
:FOLDback
[:MODE] OFF|CC|CV
:DELay <NRf+>
:ILC
:MODE <bool>
:TTLTrg
:MODE OFF|FSTR|TRIG
:RELay {1|2}
[:STATe] <bool>
:MODE?
+
functions. For a full command description refer to section
+
series commands:
Description
Aborts the triggered action
Display ON/OFF*
Display Flash
Set the output current for all power supplies
Set the output voltage for all power supplies
Enables/disables the all power supplies output
Recall setting for all power supplies
Reset all power supplies
Save settings for all power supplies
Trigger initiate
Enable/disable continuously trigger*
Couple for all Z
+
Select the power supply for communication*
Returns the measured output current
Returns the measured output voltage
Returns the measured output power
Enables/disable the supply output*
Programs the Power-ON state*
Resets latched protection
Set operation protection mode*
Set protection delay*
Enables/disable analog output ON/OFF control*
Set output trigger mode*
Set control pins status*
Returns the operation mode CV/CC/OFF
8
power supplies
Need help?
Do you have a question about the Z+ Series and is the answer not in the manual?