11.4

Sensor List

Table 11-3 Sensor List
Sensor
Inlet_Temp
Outlet_Temp
CPUn_Temp
CPUn_VR_Temp
CPUn_DIMM_Temp
CPUN_DIMMVR_Temp
PSUn_Temp
HDD_MAX_Temp
OCP_Temp
HDD_BP2_Temp
RAID_Temp
GPUn_Temp
PCIe_Zone_Inlet
PCIe_Zone_Temp
MB_Outlet_Temp
HDD_BP0_Temp
HDD_BP1_Temp
SYS_12V
Description
Air inlet temperature
Air outlet temperature
CPUn core temperature
CPUn VR temperature
CPUn DIMM temperature
CPUn DIMM VR temperature
PSUn temperature
Maximum temperature among all
drives
OCP card temperature
HDD BP2 backplane temperature
Current maximum temperature
on the RAID controller card
Current maximum temperature
on the GPU card
PCIe zone inlet temperature
PCIe zone central temperature
Motherboard outlet temperature
HDD BP0 backplane temperature
HDD BP1 backplane temperature
12 V voltage supplied by
motherboard to CPU
60
Sensor Location
Right mounting ear
BMC card
CPUn
n indicates the CPU
number with a value
of 0 - 1
CPUn
n indicates the CPU
number with a value
of 0 - 1
DIMM (CPUn)
n indicates the CPU
number with a value
of 0 - 1
DIMM (CPUn)
n indicates the CPU
number with a value
of 0 - 1
The corresponding
power supply for
PSUn
n indicates the PSU
number with a value
of 0 - 3
Drive attached to the
drive backplane
OCP card
HDD BP2 backplane
PCIe RAID controller
card
PCIe GPU card
M.2 backplane
Motherboard
Motherboard
HDD BP0 backplane
HDD BP1 backplane
Motherboard