12. Move to menu Hardware options.
Set or select the following options:
- Unlock output number
- Zone number
- Monitor second door zone (if required)
- Forced output number (if required)
- Shunt zone numbers (if required)
- Warning output number (if required)
- DOTL zone number (if required)
- DOTL output number (if required)
- Request To Exit zone number (if required)
- Interlock zone numbers (if required)
- Areas assigned to door (if required)
- Alarm output number (if required)
13. When out of the Hardware options, press 0 [ENTER] to leave the menus in
Door options. Press [ENTER] again to leave the Door options. Press 0
[ENTER] again to leave the four-door/four-lift programming menu.
14. Set-up the required door groups in the Advisor Master user program
(menu 20)
15. Program users that require access control functions (door group)
16. Program zones available on the 4-Door DGP
Advanced settings
Add alarm control functions
In the Advisor Master installer programming:
•
Program timezones required for alarm control functions (used in alarm
groups)
•
Program alarm groups (if required) for access control functions
In the four-door/four-lift programming menu:
•
Select menu 2-Door / Lift options and select the door to program
•
Move to menu Alarm control
•
Enter the required Alarm group
•
Select the required Alarm control
•
Select if Entry or Exit denied if area armed
•
Select the Authorised RAS on the system databus (if required)
Assign the alarm groups to users that should have alarm control.
4
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide