Drolet DB04820 Installation And Operation Manual page 46

Chic-choc wood burning cookstove
Hide thumbs Also See for DB04820:
Table of Contents

Advertisement

APPLIANCE CLEARANCES (INSTALLATION
WITH SINGLE WALL PIPE CONNECTOR)
Canada
A
13" (330 mm)
B
15" (381 mm)
C
11" (279 mm)
L
84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
If the side wall is on the combustion chamber side
DISTANCES
FROM PIPE CONNECTOR WITH
3
SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
51-1/4" (1302 mm)
F
18" (457 mm)
If the side wall is on the oven side
DISTANCES
FROM PIPE CONNECTOR WITH
3
SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
19" (483 mm)
F
18" (457 mm)
3
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Page 46
USA
13" (330 mm)
15" (381 mm)
11" (279 mm)
84" (213 cm)
USA
18" (457 mm)
51-1/4" (1302 mm)
18" (457 mm)
USA
18" (457 mm)
19" (483 mm)
18" (457 mm)
Installation and operation manual – Chic-Choc woodburning cookstove
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
Canada
A
7-1/2" (191 mm)
B
15" (381 mm)
C
4" (102 mm)
L
84" (213 cm)
DISTANCES
FROM PIPE CONNECTOR WITH
3
DOUBLE WALL PIPE CONNECTOR
Canada
D
12" (305 mm)
E
50-3/4" (1289 mm)
F
10-1/2" (267 mm)
DISTANCES
FROM PIPE CONNECTOR WITH
3
DOUBLE WALL PIPE CONNECTOR
Canada
D
12" (305 mm)
E
18-1/2" (470 mm)
F
10-1/2" (267 mm)
USA
7-1/2" (191 mm)
15" (381 mm)
4" (102 mm)
84" (213 cm)
USA
12" (305 mm)
50-3/4" (1289 mm)
10-1/2" (267 mm)
USA
12" (305 mm)
18-1/2" (470 mm)
10-1/2" (267 mm)

Advertisement

Table of Contents
loading

Table of Contents