Clearances For Shield Installation - Drolet DB04820 Installation And Operation Manual

Chic-choc wood burning cookstove
Hide thumbs Also See for DB04820:
Table of Contents

Advertisement

8.4

Clearances for Shield Installation

Minimum clearance
between the top of
1
the appliance and the
unprotected ceiling
Shield extension above
2
appliance
Minimum space behind the
3
shield
Clearance at the bottom of
4
the shield
Minimum clearance from
5
the top of the shield
to the ceiling:
The assembly hardware must not be located
6
at less than 200 mm (8") from the combustion
chamber central axis
Shield edges clearances
7
from the side and back
walls for ceiling shield
Shield overtaking beyond
8
the sides of the appliance
3
1
Figure 22: Clearances with Heat Shield – Face
Installation and operation manual – Chic-Choc woodburning cookstove
1
1060 mm
(42-3/4")
500 mm
(20")
USA 25 mm (1")
Can. 21 mm
(7/8")
USA 25 mm (1")
Can. min. 25 mm
(1") max 76 mm
(3")
76 mm (3")
75 mm (3")
450 mm (18")
7
5
1
2
3
4
5
8
3
1
8
Figure 21: Clearances with Heat Shield – Top
1
Figure 23: Clearances with Heat Shield – Face
6
7
5
1
2
3
4
5
2
6
3
4
Page 53