ALC II Diagnose mode
To enter diagnose mode:
– Disconnect the battery.
– Turn main power switch in OFF position.
– Push and hold the SNL button.
– Turn main power switch in ON position.
– When DIAGNOSE is on – release the SNL button.
– Reconnect battery.
To exit DIAGNOSE mode: Push the SNL button.
Changing VALUE, use UP or DOWN push button. (Value 16 – 31 = flashing value).
VALUE:
Floor indicator
0
–
1
Floor
2
Speed
3
Car S1 type
4
Car S2 type
5
Car #S1
6
Car #S2
7
Base S1 type
8
Base S2 type
9
Base #S1
10
Base #S2
11
DC voltage
12
DC voltage
13
Battery voltage
14
Battery voltage
15
Base-Car error
16
–
17
System temperature
18
System temperature
19
Temperature stop
20
CAN2 rx
21
CAN1 rx
22
Pulse decoder cnt.
23
Z-Pulse decoder cnt.
24
Number of Z error
25
Second
26
Car Input
27
Car Input
28
Car Exp. Input
29
Car Exp. Input
30
Base Input
31
Base Input
Number of floor.
Number of speed.
(0=None, 1=I/O, 2=Call, 3=Keyboard, 4=Car I/O)
(0=None, 1=I/O, 2=Call, 3=Keyboard, 4=Car I/O)
Number of card installed on expander bus (X15=10 ribbon-cable).
Number of card installed on Comm. Control Bus (X3=6-pole).
Same as above but for Base.
Internal voltage.
Internal voltage.
Internal battery voltage.
Internal battery voltage.
Number of Base-Car error.
Internal temperature.
Internal temperature.
If the unit have reached temperature max (65°C) counter.
Can communication line 2.
Can communication line 1.
Decoder pulse count.
Decoder pulse count.
Decoder error count.
Second counter.
Input in hex value.
Input in hex value.
1:st connected card in loop with
10-part connector connection.
1:st connected card in loop with
6-part wire connection.
ALIMAK 35077 - 1/12
(The integer part)
(The decimal)
(The integer part)
(The decimal)
(0–31)
(The denary part)
(The unit part)
(0–31)
(0–31)
(0–31)
(0–31)
(230VAC X14:1–4)
(X11.1–X11.6)
(230VAC X14:1–4)
(X11.1–X11.6)
(X0)
(X3)
A
17
Need help?
Do you have a question about the ALC II and is the answer not in the manual?