For more information, see the web guide controller operating instructions. The sensor must only be used in accordance with its intended purpose and in a technically flawless conditions. The sensor must not be changed or opened. www.maxcess.eu DSE-11 MI 1080 1 A...
A digital production data acquisition to Fife D-MAXE controller extends the range of applications for the sensor inside the digital network environment. Additional sensor data can be provided to other hardware equipment if the Fife D-MAXE is linked appropriately to the network. MI 1080 1 A DSE-11 www.maxcess.eu...
The signal word CAUTION refers to a possible danger which could lead to slight to moderate injury. The signal word ATTENTION refers to a possible danger which could lead to material damage. www.maxcess.eu DSE-11 MI 1080 1 A...
Keep for future use. Additional markings – Bulleted list ∙ Instructions 1. Instructions which must be processed in the specified order 2. End of the instructions Reference or cross-reference Note: Reference to important information. MI 1080 1 A DSE-11 www.maxcess.eu...
The electrician is specially trained for the field in which he or she works and is familiar with the relevant standards and regulations. www.maxcess.eu DSE-11 MI 1080 1 A...
These risks must be recorded in a risk assessment by the machine/system builder and taken into consideration in the operating instructions. MI 1080 1 A DSE-11 www.maxcess.eu...
– Do not place close to strong magnetic fields: The electronic components may be damaged. – Do not place close to strong electrostatic fields: The electronic components may be damaged. – Not in places where there is a risk of explosions. www.maxcess.eu DSE-11 MI 1080 1 A...
A large variety of assembly options are possible in connection with the various sensor mountings. ATTENTION Tighten the M8 fastening screws to a max. torque of 9Nm. Tighten the M5 fastening screws to a max. torque of 3Nm. MI 1080 1 A DSE-11 www.maxcess.eu...
Page 11
55 Sensor bracket type MB* Square bar Sensor max. bracket length MB-20 1600 15,5 MB-25 2200 18,5 41,5 18,5 1 – square bar Figure 3.2: Type MB Other dimensions are possible upon request. www.maxcess.eu DSE-11 MI 1080 1 A...
(PELV). – The negative potential must be connected to ground. – The sensor housing must be grounded via the cable screen. see also the drawing for the sensor cable in the system documentation MI 1080 1 A DSE-11 www.maxcess.eu...
Depending on the material of the web that is being guided, it is possible that the web edge could grind against the inside of the sensor fork, resulting in notches and incisions on the sensor. www.maxcess.eu DSE-11 MI 1080 1 A...
The LED on which the edge of the material web is located flickers. The LED(s) of the covered area(s) is/are lit. Example B Example A Example B flickers flickers 1 Material web Figure 4.1: Sensor DSE-11 MI 1080 1 A DSE-11 www.maxcess.eu...
3. Unscrew the sensor from its bracket. 4. Store the sensor in a cool, clean and dry place. Ambient conditions, page 7-1 Dispose of the sensor according to your national requirements. www.maxcess.eu DSE-11 MI 1080 1 A...
Setup error/no setup data Amplitude of measuring signal too The error cannot be corrected by the customer. high Service required or the sensor must be sent to Amplitude of measuring signal too Fife-Tidland GmbH. General hardware error MI 1080 1 A DSE-11 www.maxcess.eu...
Sensor field of view 10mm Linearity 5% max. error (at 20% .. 80% of signal) Web plane change 5% max. error (20% .. 80% of gap width) Temperature error 2% (at 10°C .. 50°C) www.maxcess.eu DSE-11 MI 1080 1 A...
3 P-GND 4 Output signal (analogue or RS-485) Figure 7.1: M12 connector Standards The DSE-11 sensor was constructed in accordance with the standards and regulations of the European Union. A Declaration of Conformity is available. MI 1080 1 A DSE-11 www.maxcess.eu...
Need help?
Do you have a question about the FIFE DSE-11 and is the answer not in the manual?