Maxcess FIFE SE-44R Operating Instructions Manual

Maxcess FIFE SE-44R Operating Instructions Manual

Ultrasonic sensor

Advertisement

FIFE GUIDING SOLUTIONS
FIFE SE-44R / SE-44
Ultrasonic Sensor
Operating Instructions
EN
MI 1026 1 A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIFE SE-44R and is the answer not in the manual?

Questions and answers

Summary of Contents for Maxcess FIFE SE-44R

  • Page 1 FIFE GUIDING SOLUTIONS FIFE SE-44R / SE-44 Ultrasonic Sensor Operating Instructions MI 1026 1 A...
  • Page 2: Table Of Contents

    Addresses ............7-1 MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 3: Introduction

    The SE-44 sensor must only be used in accordance with its intended purpose and in a technically flawless conditions. The SE-44 sensor must not be changed or opened www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 4: Improper Usage

    1 – Receiver 2 – Sensor field of view 3 – Source GW- Gap width GL - Throat length Figure 1.1: Sensor SE-44 MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 5: Safety Instructions

    The signal word WARNING refers to the danger of moderate to sever bodily injuries. The signal word CAUTION refers to the danger of slight to moderate bodily injuries or material damage. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 6: Symbols

    ∙ Electrical connections should always be made or disconnected on the sensor while there is no electrical power in the system. Failure to observe these instruction may result in damage to the sensor. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 7: Maintenance

    ∙ Danger of injury by crushing Maintenance work must only be performed on the sensor when the power is turned off and the machine is stopped and protected against being turned on again. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 8: Installation

    – Protection Class: IP40 – Operating temperature: 0°C ... 60°C – Relative humidity: up to 85% non-condensing – Operating altitude: max. 5000m – Not in places where there is a risk of explosions. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 9: Dimensions

    Sensor mounts of types M and MO are available for various square bars for assembling the SE-44 sensor with M8 or 7/16 drill holes www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 10 Using long bolts introduces the risk of a short-circuit and destroying the electronics that are located inside the housing. Please note when assembling sensor SE-44 that only the original M5*8 bolts or similar ones should be used. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 11: Sensor Alignment

    55° to the web. For optimal performance of the figure 3.3) sensor, the angle must be 45° (see ϕ = 45° 1 – Web 2 - Sensor axis Figure 3.3: Sensor alignment www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 12: Electrical Connection

    The sensor must be connected to the web guide controller according to the system diagram in the system documentation. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 13: Operation

    Operating Instructions for the web guide controller. Before the SE-44 is used for working with acoustically transparent material, the sensor must always be calibrated to the contrast with the web guide controller. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 14: Maintenance

    ∙ Disconnect the signal cable from the sensor. ∙ Unscrew the sensor from its bracket. ∙ Store the sensor in a cool, clean and dry place. Dispose of the sensor according to your national requirements. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 15: Technical Data

    10mm (Sensor field of view) Linearity 10% max. error (10% .. 90%) Web plane change 5% max. error (at 45° angle between web and sensor) Temperature error 7% (at 10°C .. 50°C) www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
  • Page 16: Electrical Connection

    Housing = shield Figure 6.2: M9 female connector, SE-44R Standards The SE-44 sensor was constructed in accordance with the standards and regulations of the European Union. A Declaration of Conformity is available. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
  • Page 17: Service

    48683 Ahaus Germany Germany Phone: +49 - 6195 - 7002 - 0 Fax: +49 - 6195 - 3018 E-Mail: service@maxcess.eu Web: www.maxcess.eu Fife Corporation Post Office Box 26508 Oklahoma City, OK 73126, USA Phone: +1 - 405 - 755 - 1600...
  • Page 18 CHINA JAPAN INDIA AND AFRICA AND SOUTH AMERICA Tel +49.6195.7002.0 Tel +1.405.755.1600 Tel +86.756.881.9398 Tel +81.43.421.1622 Tel +91.22.27602633 Fax +49.6195.3018 Fax +1.405.755.8425 Fax +86.756.881.9393 Fax +81.43.421.2895 Fax +91.22.27602634 sales@maxcess.eu sales@maxcessintl.com info@maxcessintl.com.cn japan@maxcessintl.com india@maxcessintl.com www.maxcess.eu www.maxcessintl.com www.maxcess.jp www.maxcess.in © 2016 Maxcess...

This manual is also suitable for:

Fife se-44Fife m289867