The SE-44 sensor must only be used in accordance with its intended purpose and in a technically flawless conditions. The SE-44 sensor must not be changed or opened www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
The signal word WARNING refers to the danger of moderate to sever bodily injuries. The signal word CAUTION refers to the danger of slight to moderate bodily injuries or material damage. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
∙ Electrical connections should always be made or disconnected on the sensor while there is no electrical power in the system. Failure to observe these instruction may result in damage to the sensor. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
∙ Danger of injury by crushing Maintenance work must only be performed on the sensor when the power is turned off and the machine is stopped and protected against being turned on again. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
– Protection Class: IP40 – Operating temperature: 0°C ... 60°C – Relative humidity: up to 85% non-condensing – Operating altitude: max. 5000m – Not in places where there is a risk of explosions. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
Sensor mounts of types M and MO are available for various square bars for assembling the SE-44 sensor with M8 or 7/16 drill holes www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
Page 10
Using long bolts introduces the risk of a short-circuit and destroying the electronics that are located inside the housing. Please note when assembling sensor SE-44 that only the original M5*8 bolts or similar ones should be used. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
55° to the web. For optimal performance of the figure 3.3) sensor, the angle must be 45° (see ϕ = 45° 1 – Web 2 - Sensor axis Figure 3.3: Sensor alignment www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
The sensor must be connected to the web guide controller according to the system diagram in the system documentation. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
Operating Instructions for the web guide controller. Before the SE-44 is used for working with acoustically transparent material, the sensor must always be calibrated to the contrast with the web guide controller. www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
∙ Disconnect the signal cable from the sensor. ∙ Unscrew the sensor from its bracket. ∙ Store the sensor in a cool, clean and dry place. Dispose of the sensor according to your national requirements. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...
10mm (Sensor field of view) Linearity 10% max. error (10% .. 90%) Web plane change 5% max. error (at 45° angle between web and sensor) Temperature error 7% (at 10°C .. 50°C) www.maxcess.eu SE-44R / SE-44 MI 1026 1 A Ultrasonic Sensor...
Housing = shield Figure 6.2: M9 female connector, SE-44R Standards The SE-44 sensor was constructed in accordance with the standards and regulations of the European Union. A Declaration of Conformity is available. MI 1026 1 A SE-44R / SE-44 www.maxcess.eu Ultrasonic Sensor...