Install the hot-plug fan or fan blank into fan bay 1.
9.
M.2 SSD Enablement Board option
The M.2 enablement board is supported in slot 1 or 2 with the full-height bracket on the primary riser cage
and in slot 3 with the low-profile bracket on the secondary riser cage.
Installing an SSD module on the M.2 SSD Enablement Board
1.
Power down the server (on page 21).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Extend the server from the rack (on page 21).
4.
Remove the access panel (on page 22).
5.
Remove the PCIe riser cage
6.
Remove the expansion slot blank
IMPORTANT: For management and monitoring of the SSD modules, use the HPE Smart
Storage Administrator (http://www.hpe.com/servers/ssa).
("Remove the PCI riser
("Removing the expansion slot
cage" on page 23).
blanks" on page 91).
Hardware options installation 100