Ack Nak Retry Count - Datalogic PowerScan PD96 Series Product Reference Manual

Industrial corded and cordless handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD96 Series:
Table of Contents

Advertisement

REFERENCES

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due to
a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables
the count, and a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 =
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
4. Scan the bar code: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea-
ture.
Table 12 - ACK NAK Retry Count Setting Examples
STEP
1
2
3
4
5
6
278
POWERSCAN™ PD/PM96XX
005, 20 = 020, etc.
Mode.
the number which was determined in the steps above. You will hear a two-beep
indication after the last character.
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
ACTION
Desired Setting
Pad with leading zero(es)
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK RETRY COUNT SETTING
Scan three characters
from Appendix D
Scan ENTER/EXIT PROGRAMMING MODE
EXAMPLES
Disable Retry
3 Retries
Count
000
003
'0', '0' and '0' '0', '0' and '3' '0', '5' and '4' '2', '5' and '5'
, that represent
Appendix D
Unlimited
54 Retries
Retries
054
255

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents