ENTER/EXIT PROGRAMMING MODE

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the
symbology ID to match those required for EAN-13.
$CAB3B00
UPC-A to EAN-13 = Expand

UPC-A Number System Character Transmission

This feature enables/disables transmission of the UPC-A number system character.
$CABNS00
UPC-A Number System Character = Transmit
114
POWERSCAN™ PD/PM96XX
UPC-A to EAN-13 = Don't Expand
$CAB3B01
UPC-A Number System Character = Do not transmit
$CABNS01