Specifications

Function
DC Current
AC Current
True RMS (50Hz to 60
Hz)
DC Voltage
AC Voltage
True RMS (50 Hz to
1000 Hz)
Resistance
Capacitance
Frequency
Duty Cycle
Temp
(type-K)
Range& Resolution
400.00 ADC
1500.0 ADC
400.00 AAC
1500.0 AAC
All AC current ranges are specified from 5% to 100% of range
400.00 mVDC
4.0000 VDC
40.000 VDC
400. 00 VDC
1000.0 VDC
400.00 mVAC
4.0000 VAC
40.000 VAC
400. 00 VAC
750.0 VAC
All AC voltage ranges are specified from 5% to 100% of range
400.00 Ω
4.0000 kΩ
40.000 kΩ
400.00 kΩ
4.0000 MΩ
40.000 MΩ
400.00 nF
4000.0 nF
40.00.μF
400.0.μF
4.000 mF
20.00 mF
40.00 mF
40.000 Hz
400.00 Hz
4.0000 kHz
40.000 kHz
400.00 kHz
4.0000MHz
40.000MHz
Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80%
10.0 to 95.0%
Pulse width: 100µs - 100ms, Frequency: 10Hz to 100kHz
-100.0 to 1000.0°C
-148.0 to 1832.0°F
Accuracy (% of reading)
± (2.0% +30digits)
± (2.5% +30digits)
± (2.8% +30digits)
± (0.1% + 5 digits)
± (0.1% + 4 digits)
± (0.5% + 4 digits)
± (0.8% + 40 digits)(50/60Hz)
± (1.0% + 30 digits)
± (0.5% + 9 digits)
± (1.0% + 4 digits)
± (2.0% + 10 digits)
± (3.0% + 10 digits)
±(3.5% reading + 40 digits)
±(3.5% reading + 10 digits)
±(5% reading + 10 digits)
Not specified
±(0.3% reading + 2 digits)
duty cycle and > 100kHz.
± (1.0% reading + 2 digits)
±(1.0% reading + 2.5 °C)
±(1.0% reading + 4.5°F)
(probe accuracy not included)