Advertisement

FLIR MODEL MR60
MOISTURE METER PRO
USER MANUAL
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MR60 and is the answer not in the manual?

Questions and answers

dale
February 13, 2025

My Flir MR60 is powering up but other than a blue line at the top and a blue line at the bottom of the screen, it is not operating. It will then power off after a min.

1 comments:
Mr. Anderson
February 13, 2025

If the FLIR MR60 powers up but only shows blue lines on the screen and then turns off after a minute, the issue could be related to a low battery. The manual states that if the battery voltage is low, the meter may not function properly. Charging the battery fully before use is recommended. If the problem persists after charging, a firmware issue may also be a possibility, in which case updating the firmware could help resolve the issue.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for FLIR MR60

  • Page 1 USER MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 FLIR MODEL MR60 Visit us at www.TestEquipmentDepot.com MOISTURE METER PRO...
  • Page 2: Table Of Contents

    5.1.1 Auto Power OFF (APO) 5.2 Moisture Measurements 5.2.1 Moisture Measurement Overview 5.2.2 Moisture Display Overview 5.2.3 Moisture Menu 5.2.4 External Pin Probe Moisture Measurements 5.2.5 Internal Moisture Sensor Measurements (Pinless) 5.2.6 Reference Mode Moisture Measurements FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 3 7.1 General Specifications 7.2 Moisture Meter Specifications TECHNICAL SUPPORT MATERIAL GROUPS 9.1 Common Names of Timbers (BS888/589:1973) with MR60 Group Nos. 9.2 Botanical names of timbers with MR60 program group numbers 9.3 %WME Table (% Wood Moisture Equivalent) 10. WARRANTY 10.1 FLIR Test &...
  • Page 4: Disclaimers

    1. Disclaimers 1.1 Copyright © 2016 FLIR Systems, Inc. All rights reserved worldwide. No parts of the software including source code may be reproduced, transmitted, transcribed or translated into any language or computer language in any form or by any means, electronic, magnetic, optical, manual or otherwise, without the prior written permission of FLIR Systems.
  • Page 5: Safety

     Before operating the device, you must read, understand, and follow all instructions, dangers, warnings, cautions, and notes.  FLIR Systems reserves the right to discontinue models, parts or accessories, and other items, or to change specifications at any time without prior notice.
  • Page 6: Introduction

    3. Introduction Thank you for selecting the FLIR MR60 Moisture Meter Pro. The FLIR MR60 Moisture Meter Pro is an easy-to-use pin and pinless moisture meter with advanced functionality to meet all your professional measurement needs. An integrated pinless sensor and an external pin probe (MR02) provide the flexibility to take either destructive or non-destructive measurements.
  • Page 7: Meter Descriptions

    Hold button Power button USB, external probe jack, and charge LED Internal Pinless Moisture sensor (back) 10. Micro USB cable jack 11. External probe jack (RJ45) 12. Charging LED Fig. 4-1 Meter Description FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 8: Control Button Descriptions

    Pin mode is selected and the Set Reference function is only available when Pinless mode is selected. Settings mode items: Language, High Alarm, Auto Power OFF, Date & Time, Meter Information, and Help contact screen. FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 9: Operation

    (rear) or by connecting an external probe. A standard external pin probe is included which connects to the MR60 via the jack at the bottom of the meter. NOTE: Objects in close proximity to the internal pinless moisture sensor (located on the rear of the unit) will affect the reading on the display;...
  • Page 10: Moisture Display Overview

    Pinless mode must be selected when using the internal (rear) sensor. Note the pinless icon on the main display when this mode is selected. Set Reference Select this mode to store the current reading as a reference/comparator value (Pinless mode only). FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 11: External Pin Probe Moisture Measurements

    Notes on External Pin Probe Moisture measurements The MR60 will display accurate external pin probe readings in the 7% to 30% range, depending on the tested material. Moisture Content readings below 6% will display as 0% for all materials and the maximum specified range is dependent on the fiber saturation point for specific species.
  • Page 12: Reference Mode Moisture Measurements

    The log.csv file can be downloaded to a computer or other compatible device using the MR60 USB port (bottom of meter, under flap) and supplied USB cable. See Fig. 5-3 for an example log file.
  • Page 13: High Moisture Alarm

    Fig. 5-3 Log file example 5.4 High Moisture Alarm The MR60 offers a High Moisture Alarm where an audible and visual alert activates when the moisture reading exceeds the programmed high limit. Press the Select button to access the Main Menu...
  • Page 14: Settings Menu

    Settings menu; use the down navigation button to scroll down: HELP SCREEN. Scroll to HELP and press the Select button to view the company contact information. Press the back button to return to the Settings menu. FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 15: Maintenance

    As with most electronic products, this equipment must be disposed of in an environmentally friendly way, and in accordance with existing regulations for electronic waste. Please contact your local FLIR Systems representative for more details. FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 16: Updating The Mr60 Firmware

    6.3 Updating the MR60 firmware The MR60 firmware can be updated in the field by the user, without the need for sending the unit in for service. If assistance is required, the user can contact a FLIR technical specialist (see Section 8).
  • Page 17: Specifications

    CE, FCC Class B, UL, RCM Included accessories MR02 Standard Pin Probe, Quick Start Guide, International USB charger, and USB cable Language options Meter display text can be shown in any of fourteen (14) languages FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 18: Moisture Meter Specifications

    **Accuracy spec. applies to pin probe moisture measurements taken on wood whose temperature is 20°C (68°F). Add 0.1% to the accuracy spec. for each °C below 20°C or subtract 0.1% for each °C above 20°C. FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 19: Material Groups

    9. Material Groups 9.1 Common Names of Timbers (BS888/589:1973) with MR60 Group Nos. Notes: Group 9 is for plywood, drywall, and oriented strand board (OSB) Group 10 is for brick, cement screed, and concrete Group 11 is for cement mortar, anhydrite screed, lime mortar, and plaster...
  • Page 20 Guarea, Black Opepe Walnut, American Guarea, White Padang Walnut, European Gum, American Red Padauk, African Walnut, New Guinea Gum, Saligna Panga Panga Walnut, Queensland Gum, Southern Persimmon Wandoo Gum, Spotted Pillarwood Wawa Whitewood FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 21: Botanical Names Of Timbers With Mr60 Program Group Numbers

    9.2 Botanical names of timbers with MR60 program group numbers Picea jezoensis (8- Abies alba Eucalyptus acmenicides 18%mc) Abies grandis Eucalyptus crebra Picea sitchensis Abies procera Eucalyptus diversicolor Pinus caribaea Acanthopanex ricinifolius Eucalyptus globulus Pinus contorta Acer macrophyllum Eucalyptus maculate...
  • Page 22 Tsuga heterophylia Endiandra palmerstoni Paulownia tomentosa Ulmus americana Entandrophragma angolense Pericopsis elata Ulmus procera Entandrophragma cylindricum Picaenia excelsa Ulmus thomasii Entandrophragma utile Picea abies Xylia dolabriformis Erythrophleum spp Picea jezoensis (18-28%mc) Zelkova serrata FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 23: Wme Table (% Wood Moisture Equivalent)

    27.4 20.8 20.4 25.8 20.5 24.2 27.8 21.2 19.4 22.7 26.3 ≈23 25.3 22.4 22.3 20.1 23.9 27.3 26.5 23.3 23.4 20.8 24.7 28.1 24.4 24.8 21.7 25.9 29.6 25.6 26.3 22.9 27.1 FLIR MR60 USER MANUAL Document Identifier: MR60-en-US_AB...
  • Page 24: Warranty

    Any Product that is repaired or replaced under warranty is covered under this 2-Year Limited Warranty for one hundred eighty days (180) days from the date of return shipment by FLIR or for the remaining duration of the applicable Warranty Period, whichever is longer.
  • Page 25 RMA instructions provided by FLIR including but not limited to adequately packaging the Product for shipment to FLIR and for all packaging and shipping costs. FLIR will pay for returning to Purchaser any Product that FLIR repairs or replaces under warranty.