Operational Instruction
(Translation)
Commissioning
Before commissioning, check that:
The device has been installed in compli-
ance with regulations.
The enclosure is not damaged.
The connection has been established
properly.
The cables have been laid correctly.
All screws have been tightened securely.
The device functions perfectly.
Transport, Storage
Damage to the Ex d control station through
incorrect transport or incorrect storage.
Transport and storage is permissible in
original packaging only.

Operation

Death or serious injury through improper
use.
The Ex d control station may be operated
only within the technical limits that apply to
it (see page 1).
Maintenance and Fault Clearance
Death or serious injury through damaged
flameproof encapsulation.
The threaded gaps must be protected.
They must not be machined or varnished
at any time later.
Defective parts in the flameproof encapsu-
lation must be replaced with original parts
immediately.
Risk of injury due to incorrect proceedings.
Only authorized qualified personnel are
allowed to do any of the work relating to
maintenance and fault clearance.
IEC/EN 60079-17 must be observed.
BARTEC
GmbH Max-Eyth-Straße 16
97980 Bad Mergentheim
Germany
Ex d Control Station
Maintenance work
The operator of the Ex d control station must
keep it in good condition, operate it correctly,
monitor it, and clean it regularly.
Visually inspect the threaded gap.
Visually inspect the flameproof encapsu-
lation for damage.
Check sealings for effectiveness.
Replace old or damaged sealings with
new original seals.
Check that the connection terminals,
cable & conductor entries are secure.
Note
In the course of maintenance particular atten-
tion must be paid to checking that the parts
essential for the type of protection and proper
functioning are in good condition.
Fault Clearance
The Ex d control station is defective if the
flameproof encapsulation is damaged and/or if
one of the components does not function any
longer.
In this case:
Immediately replace the defective parts in
the flameproof encapsulation with original
parts.
Replace or repair the defective compo-
nents with original parts.
Note
Follow the components mounting instructi-
ons/operating instructions to replace or repair
the components.
Tel.: +49 7931 597-0
info@bartec.de
Fax: +49 7931 597-119
www.bartec.de
Type 07-4230-..../...
Accessories, Spare Parts
See BARTEC catalogue.
Disposal
The components in the Ex d control station
contain metal and plastic parts.
Therefore the statutory requirements for dispos-
ing of electronic scrap must be observed (e.g.
disposal by an approved disposal company).