7-1-1 Environmental conditions

Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Vibration

7-1-2 Installing the linear servomotor

(1) Installing the primary side
1) Dimensions for tie-in with secondary side
∗1. The H dimensions indicate the (primary side height dimensions) + (secondary side height
dimensions) + (clearance length: 0.5[mm]).
2) Example of the installation procedures
An example of the installation procedures is shown below.
1. Installing primary side where there is no secondary side
4. Installing remaining secondary side
CAUTION
Chapter 7 Installation
0°C to +40°C
(with no freezing)
80% (RH) or less (with no dew condensation)
–15°C to +50°C (with no freezing)
90% (RH) or less (with no dew condensation)
Indoors (Where unit is not subject to direct sunlight)
With no corrosive gas, combustible gas or dust
2
49m/s
or less
Primary side center
0.5[mm] or less
Secondary side center
1. Installing the primary side where there is no secondary side, as shown
above, is recommended to avoid risks posed by the attraction force of the
permanent magnet between the primary side and secondary side.
2. If the primary side must be installed over the secondary side, use a material
handling device, such as a crane, which can sufficiently withstand the load
such as the attraction force.
3. Note that an attraction force will be generated even after the primary side
has been installed and is moved over to the secondary side.
Conditions
Primary side center
LM-NP2 : Center of installation screw pitch
LM-NP4 : Installation screw at center position
1. Installing secondary side (part)
3. Moving over secondary side where primary side is installed.
7–3
0.1
A
0.1
A
0.1