Mitsubishi Electric MELDAS MDS-B Series Instruction Manual page 147

Linear servo system
Table of Contents

Advertisement

No.
Abbrev.
Parameter name
SV032
TOF
Thrust offset
SV045
TRUB
Current
compensation/
frictional force
SV059
TCNV
Estimated thrust
gain
SV060
TLMT
G0 collision
detection level
POINT
 
Chapter 10 Adjustment
Unit
Stall %
Set the unbalance thrust amount of an axis having an
(rated
unbalanced thrust, such as a vertical axis, as a percentage
current %)
(%) in respect to the stall rated current.
Stall %
When using the collision detection function, set the frictional
(rated
force as a percentage in respect to the stall rated current.
current %)
The low-order 8 bits are used.
Set 0 when not using the collision detection function.
When using the collision detection function, set the estimated
thrust gain.
When SV035:SSFS4/clt is set to 1, the setting value guide will
display at MPOF on the Servo Monitor screen.
Set 0 when not using the collision detection function.
Stall %
When using the collision detection function, set the collision
(rated
detection level for the method G0 modal as a percentage in
current %)
respect to the stall rated current.
Set 0 when not using the collision detection function.
1. Even when validated, this function does not guarantee that the machine will
not break and does not guarantee the machine accuracy after a collision.
Thus, the conventional caution must be taken during machine operation to
prevent accidents.
2. If the collision detection limit is set at the extreme limit, an incorrect
detection may be made even in the normal state. Thus, set the collision
detection level to a slightly larger value.
3. After adjusting the machine or replacing the motor or detector replaced
during maintenance, adjust the collision detection related parameters again.
4. If the detector resolution has been changed due to replacement of the
detector, or when the position control system has been changed (changed
between the closed loop or semi-closed loop, etc.), the SV059: TCNV
estimated thrust gain must be changed.
Explanation
10–36
Setting range
–100 to 100
0 to 100
0 to 32767
0 to 100

Hide quick links: