CPU error (SUB):
Alarm No.
An error was detected in the data stored in the EEPROM of an absolute position
1B
linear scale connected to the SUB side.
Investigation details
1 Wiggle the connectors by hand to check
whether the absolute position linear
scale connectors (driver side and scale
side) are disconnected.
2 Turn the power OFF, and check the
detector cable connection with a tester.
3 Connect to another normal axis driver,
and check whether the fault is on the
driver side or scale side.
4 Check if there is any abnormality in the
unit's ambient environment.
(Ex. Ambient temperature, noise,
grounding)
EEPROM/LED error (SUB):
Alarm No.
An error was detected in the EEPROM of an absolute position linear position linear
1C
scale connected to the SUB side.
Investigation details
1 Check the alarm No. "1B" items.
Data error (SUB):
Alarm No.
An error was detected within one rotation position of an absolute position linear
1D
position linear scale connected to the SUB side.
Investigation details
1 Check the alarm No. "1B" items.
ROM, RAM/thermal error (SUB):
Alarm No.
A ROM/RAM error was detected in the absolute position linear scale connected to
1E
the SUB side.
Investigation details
1 Check the alarm No. "1B" items.
Serial detector communication error (SUB)
Alarm No.
Communication was cut off with the detector in the absolute position scale connected
1F
to the SUB side.
Investigation details
1 Check items 2 and following for alarm
No. "18".
Chapter 11 Troubleshooting
Investigation results
The connector is disconnected (or
loose).
The connector is not disconnected.
There is a connection fault.
The connection is normal.
The alarm is on the driver side.
The alarm is on the absolute position
linear scale side.
No abnormality is found in particular.
An abnormality was found in the
ambient environment.
Investigation results
Investigation results
Investigation results
Investigation results
11–11
Alarm check timing
f1
f2
Remedies
Correctly install.
Investigate item 2.
Replace the detector cable.
Investigate item 3.
Replace the drive unit.
Investigate item 4.
Replace the absolute position linear scale.
Take remedies according to the causes of
the abnormality.
Ex.
High
temperature ...
Check the
cooling
fan.
Incomplete grounding .... Additionally
Alarm check timing
f1
f2
Remedies
Alarm check timing
f1
f2
Remedies
Alarm check timing
f1
f2
Remedies
Alarm check timing
f1
f2
Remedies
f3
f4
ground.
f3
f4
f3
f4
f3
f4
f3
f4